Water Heater Decoder

Rheem water heater flashing light codes

Covers Rheem and Ruud gas water heaters.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2
Carbon monoxide alarm? Get outside

Get everyone to fresh air outside right away and call 911. Stay outside until emergency responders say it is safe to go back in.3

Flames coming out of the heater, smoke, or burn marks or melted parts that might be new? Get outside

If you see flames coming out of the heater, smoke, or signs it may still be burning, get everyone out and call 911 from outside. Leave the heater and switches alone. If you find unexplained burn marks or melted parts and can’t tell whether there’s an active fire, get outside and call 911. If you know the damage is old and there are no other emergency signs, keep the heater out of use and call a licensed technician.4

Water gushing or spraying from the safety valve’s pipe, or hot spray or steam near the heater? Leave now

The relief pipe is the pipe from the heater’s pressure safety valve. Keep clear of the heater, pipe and valves, even if you can’t tell where hot spray is coming from. Leave by a safe route and call 911 from outside. A slow drip without steam or other warning signs calls for safe shutoff and a plumber.5

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Every code, by control

Standing-pilot gas valve with blue and red light

Rectangular gas control at the bottom front.

Look for a round temperature and pilot dial on the left, a spark button below it and a small STATUS window to the right. The label lists blue for a normal single blink and red for faults. Match the number list on the heater. This version ends at 8.7 Used on: Rheem Performance and comparable Rheem/Ruud atmospheric tanks covered by AP23060 or a matching chart.

No light The gas control has no pilot power. Safe to check yourself

Likely causes: The knob is off; The pilot is out; The pilot is supplying too little power

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.8

Steady light The pilot was just shut off and the pilot power cell is cooling. Safe to check yourself

Red light: Steady light.

Likely cause: The gas control knob was turned to OFF

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.8

1 flash The heater is operating normally or is in pilot mode. Safe to check yourself

Blue light: 1 flash every 3 seconds.

Next step: No service is needed for this normal pattern.8

2 flashes The pilot is lit but is supplying too little power to the gas control. Licensed technician only

Red light: 2 flashes, pattern repeats about every 3 seconds.

Likely causes: A weak pilot; A damaged pilot power cell (thermopile) or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

4 flashes The heater shut down because tank water reached the high temperature limit. Licensed technician only

Red light: 4 flashes, pattern repeats about every 3 seconds.

Likely cause: Water above the high temperature limit

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

5 flashes The gas control detected a problem with its water temperature sensor. Licensed technician only

Red light: 5 flashes, pattern repeats about every 3 seconds.

Likely cause: A failing temperature sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

7 flashes The gas valve or its control has failed. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.9

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Red light: 7 flashes, pattern repeats about every 3 seconds.

Likely cause: A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

8 flashes The control picked up a pilot flame signal at the wrong time. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.9

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Red light: 8 flashes, pattern repeats about every 3 seconds.

Likely cause: A faulty pilot flame signal

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

Honeywell PowerVent ESII

Low front valve with a round LOW to HOT temperature knob, separate ON/OFF switch and one status light.

Look for a cord and a powered blower at the vent on top. Some models have a separate display with a two-digit code. Bulletin 1627 refers to a blue status light. Use the ESII label or exact model to tell it apart from later powered-vent units. The display, when present, is separate from the valve dial.10 Used on: PowerVent ESII with the Honeywell electronic gas control. The Rheem bulletin index dates this platform from October 2010.

Bright and dim The heater is calling for heat. Safe to check yourself

Blue light: Alternating bright and dim.

Next step: No service is needed for this normal pattern.11

1 flash every 3 seconds or 12 on the screen The control received a weak flame signal. Licensed technician only

Blue light: 1 flash every 3 seconds (screen shows 12).

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.12

1 flash, about every 4 seconds The tank is up to temperature and waiting. Safe to check yourself

Blue light: 1 flash, about every 4 seconds.

Next step: No service is needed for this normal pattern.11

2 flashes or 44 on the screen The pressure switch stayed closed when it should have opened. Licensed technician only

Blue light: 2 flashes, then a 3-second pause (screen shows 44).

Likely cause: A blower pressure switch or wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.11

3 flashes or 46 on the screen The air-pressure switch reported that it stayed open. Licensed technician only

Blue light: 3 flashes, then a 3-second pause (screen shows 46).

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.11

4 flashes or 31 on the screen The tank reached its high temperature cutoff. Licensed technician only

Blue light: 4 flashes, then a 3-second pause (screen shows 31).

Likely cause: Tank temperature above the safety limit

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.11

5 flashes or 14 on the screen The control sensed a flame at the wrong time. Licensed technician only

Blue light: 5 flashes, then a 3-second pause (screen shows 14).

Likely cause: A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.12

6 flashes, then 1 or 11 on the screen The heater paused after failed attempts to light. Licensed technician only

Blue light: 6 flashes, then 1 flash, then a 3-second pause (screen shows 11).

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13

6 flashes, then 2 or 45 on the screen The heater shut down when a blower safety switch opened during operation. Licensed technician only

Blue light: 6 flashes, then 2 flashes, then a 3-second pause (screen shows 45).

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.11

6 flashes, then 3 or 13 on the screen The heater shut down after losing the flame. Licensed technician only

Blue light: 6 flashes, then 3 flashes, then a 3-second pause (screen shows 13).

Likely causes: Low gas supply pressure; A weak or faulty flame sensor; Restricted burner air

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.12

6 flashes, then 5 or 10 on the screen The heater locked out after repeated attempts to light. Licensed technician only

Blue light: 6 flashes, then 5 flashes, then a 3-second pause (screen shows 10).

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.11

7 flashes or 47 on the screen Leave the area first The heater has locked out because the flammable-vapor sensor signaled danger.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Blue light: 7 flashes, then a 3-second pause (screen shows 47).

Likely cause: Flammable vapors near the heater

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.14

8 flashes, then 1 or 49 on the screen Leave the area first The heater detected a fault in the flammable-vapor sensor circuit.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.9

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Blue light: 8 flashes, then 1 flash, then a 3-second pause (screen shows 49).

Likely cause: A faulty vapor sensor or gas control

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.14

8 flashes, then 2 or 89 on the screen The gas control detected a fault with its tank temperature readings. Licensed technician only

Blue light: 8 flashes, then 2 flashes, then a 3-second pause (screen shows 89).

Likely cause: A bad temperature probe or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.11

8 flashes, then 3 or 15 on the screen The gas control detected an electronics fault. Licensed technician only

Blue light: 8 flashes, then 3 flashes, then a 3-second pause (screen shows 15).

Likely cause: A faulty control module or temperature probe

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.11

8 flashes, then 4 or 93 on the screen The controller detected a gas valve fault. Licensed technician only

Blue light: 8 flashes, then 4 flashes, then a 3-second pause (screen shows 93).

Likely cause: A damaged or faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.11

91 The optional display lost touch with the gas valve control. Licensed technician only

Likely cause: A display connection or communication fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

Induced draft single-light control

Small single status lamp beside a round temperature dial and a separate power switch on the low-front gas valve.

A powered fan is at the top. Check the exact model and manual to tell variants apart.16 Used on: Induced draft residential gas tanks using the AP15696-3 chart.

Bright and dim The heater is calling for heat. Safe to check yourself

Alternating bright and dim.

Next step: No service is needed for this normal pattern.17

1 flash every 3 seconds The control received a weak flame signal. Licensed technician only

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

1 flash, about every 4 seconds The tank is up to temperature and waiting. Safe to check yourself

Next step: No service is needed for this normal pattern.17

2 flashes The pressure switch stayed closed when it should have opened. Licensed technician only

2 flashes, then a 3-second pause.

Likely cause: A blower pressure switch or wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

3 flashes The pressure switch or blower temperature switch stayed open. Licensed technician only

3 flashes, then a 3-second pause.

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

4 flashes The tank reached its high temperature cutoff. Licensed technician only

4 flashes, then a 3-second pause.

Likely cause: Tank temperature above the safety limit

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

5 flashes The control sensed a flame at the wrong time. Licensed technician only

5 flashes, then a 3-second pause.

Likely cause: A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

6 flashes, then 1 The heater shut down after a failed attempt to light. Licensed technician only

6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

6 flashes, then 2 The heater shut down when a blower safety switch opened during operation. Licensed technician only

6 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

6 flashes, then 3 The heater shut down after losing the flame. Licensed technician only

6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: Low gas supply pressure; A weak or faulty flame sensor; Restricted burner air

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

6 flashes, then 4 The heater shut down after sensing a flame at the wrong time. Licensed technician only

6 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

7 flashes Leave the area first The heater has locked out because the flammable-vapor sensor signaled danger.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

7 flashes, then a 3-second pause.

Likely causes: Flammable vapors near the heater; A faulty vapor sensor

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.17

8 flashes, then 1 Leave the area first The heater detected a fault in the flammable-vapor sensor circuit.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.9

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes, then 1 flash, then a 3-second pause.

Likely cause: A faulty vapor sensor or gas control

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.17

8 flashes, then 2 The gas control detected a fault with its tank temperature readings. Licensed technician only

8 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A bad temperature probe or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

8 flashes, then 3 The gas control detected an electronics fault. Licensed technician only

8 flashes, then 3 flashes, then a 3-second pause.

Likely cause: A faulty control module or temperature probe

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

8 flashes, then 4 The controller detected a gas valve fault. Licensed technician only

8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A damaged or faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

White-Rodgers Intelli-Vent Guardian PowerVent

Cream rectangular control with six little lights in a horizontal row.

The last three are marked A, B and C. The triangle is over the third light. There are blue COOLER and red HOTTER buttons below the row instead of a round dial.18 Used on: Guardian PowerVent with White-Rodgers Intelli-Vent. Bulletin 1621 dates the transition to October 2007. Ruud Professional Achiever models using AP15762 share many patterns. Match the appliance manual for lights 1, 3 and 4 or lights 1, 3, 4 and 6.

All lights flicker All six lights flickering erratically points to an unreliable or disconnected neutral connection. Licensed technician only

Likely cause: A loose or faulty neutral wire

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.19

Lights 1 and 3 on The air-pressure switch stayed closed after a call for heat began. Licensed technician only

Lights 1, 3 on, left to right.

Likely causes: A stuck pressure switch; A wiring problem

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.20

Lights 1 and 4 on The control cannot detect a proper electrical ground. Licensed technician only

Lights 1, 4 on, left to right.

Likely cause: A missing or loose ground connection

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.20

Lights 1 and 5 on The heater sensed a flame at the wrong time. Licensed technician only

Lights 1, 5 on, left to right.

Likely cause: A flame sensor or gas control fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.21

Lights 1 and 6 on Leave the area first The heater locked out after detecting flammable vapors.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Lights 1, 6 on, left to right.

Likely cause: Flammable vapors near the heater

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.22

Lights 1, 3 and 4 on The control thinks a temperature button is stuck. Licensed technician only

Lights 1, 3, 4 on, left to right.

Likely cause: A stuck button or control fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.21

Lights 1, 3 and 5 on The control detected a problem with its electrical supply wiring. Licensed technician only

Lights 1, 3, 5 on, left to right.

Likely causes: Reversed supply wires; A grounding fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.20

Lights 1, 3 and 6 on The air-pressure switch stayed open after the fan started. Licensed technician only

Lights 1, 3, 6 on, left to right.

Likely causes: A vent blockage; A blower, pressure switch or wiring problem

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.23

Lights 1, 4 and 5 on The burner failed to light or stay lit after several tries. Licensed technician only

Lights 1, 4, 5 on, left to right.

Likely causes: Poor gas supply; An igniter or flame sensor fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.23

Lights 1, 4 and 6 on Leave the area first The control detected a fault in the flammable-vapor sensor circuit.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.9

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Lights 1, 4, 6 on, left to right.

Likely causes: A damaged or disconnected vapor sensor; An electrical short

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.22

Lights 1, 5 and 6 on The controller detected a fault in its gas valve drive circuit. Licensed technician only

Lights 1, 5, 6 on, left to right.

Likely cause: An internal control fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.24

Lights 1, 3, 4 and 5 on The controller detected a fault in its internal processor. Licensed technician only

Lights 1, 3, 4, 5 on, left to right.

Likely cause: An internal control fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.24

Lights 1, 3, 4 and 6 on The tank temperature sensor circuit has a fault. Licensed technician only

Lights 1, 3, 4, 6 on, left to right.

Ruud AP15762 pattern. Rheem TB 1621 prints its sensor fault with lights 1, 3 and 4 instead.

Likely cause: An open or shorted sensor circuit

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.25

Lights 1, 3, 5 and 6 on The controller detected a fault in the electric igniter circuit. Licensed technician only

Lights 1, 3, 5, 6 on, left to right.

Likely cause: A damaged igniter or wiring

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.23

Lights 1, 4, 5 and 6 on The tank reached the high temperature cutoff. Licensed technician only

Lights 1, 4, 5, 6 on, left to right.

Likely cause: Excessive tank temperature

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.21

Lights 1, 2, 3, 4, 5 and 6 on The controller detected a fault in an internal circuit. Licensed technician only

Lights 1, 2, 3, 4, 5, 6 on, left to right.

Likely cause: An internal control fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.24

Powered flue damper gas control

Single status light beside the low-front gas valve temperature dial and separate ON/OFF switch.

Look for a motorized flap (vent damper) at the top of the metal exhaust pipe.26 Used on: 38, 40 and 50 gallon powered flue damper models in the AP15756 manual.

Bright and dim The heater is calling for heat. Safe to check yourself

Alternating bright and dim.

Next step: No service is needed for this normal pattern.27

1 flash every 3 seconds The control received a weak flame signal. Licensed technician only

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

1 flash, about every 4 seconds The tank is up to temperature and waiting. Safe to check yourself

Next step: No service is needed for this normal pattern.27

2 flashes The vent damper switch stayed closed. Licensed technician only

2 flashes, then a 3-second pause.

Likely causes: A stuck damper switch; A wiring or damper motor fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

3 flashes The vent damper switch stayed open. Licensed technician only

3 flashes, then a 3-second pause.

Likely causes: A stuck damper switch; A wiring or damper motor fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

4 flashes The tank reached its high temperature cutoff. Licensed technician only

4 flashes, then a 3-second pause.

Likely cause: Tank temperature above the safety limit

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

5 flashes The heater locked out because it did not detect a flame. Licensed technician only

5 flashes, then a 3-second pause.

Likely cause: The pilot or main gas valve failed to open

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

6 flashes, then 1 The heater shut down after a failed attempt to light. Licensed technician only

6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

6 flashes, then 2 The heater locked out when the vent damper switch opened. Licensed technician only

6 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A faulty damper or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

6 flashes, then 3 The heater shut down after losing the flame. Licensed technician only

6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: Low gas supply pressure; A weak or faulty flame sensor; Restricted burner air

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

6 flashes, then 4 The heater shut down after sensing a flame at the wrong time. Licensed technician only

6 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.28

7 flashes Leave the area first The heater has locked out because the flammable-vapor sensor signaled danger.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

7 flashes, then a 3-second pause.

Likely causes: Flammable vapors near the heater; A faulty vapor sensor

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.28

8 flashes, then 1 Leave the area first The heater detected a fault in the flammable-vapor sensor circuit.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.9

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes, then 1 flash, then a 3-second pause.

Likely cause: A faulty vapor sensor or gas control

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.28

8 flashes, then 2 The heater flagged a fault in its tank temperature cutoff circuit. Licensed technician only

8 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A faulty tank temperature probe

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.28

8 flashes, then 3 The gas control detected an electronics fault. Licensed technician only

8 flashes, then 3 flashes, then a 3-second pause.

Likely cause: A faulty control module or temperature probe

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.28

8 flashes, then 4 The controller detected a gas valve fault. Licensed technician only

8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A damaged or faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.28

Professional Classic Power Vent, single light

Low front valve with a round LOW to HOT temperature knob, separate ON/OFF switch and one status light.

Look for a cord and a powered blower at the vent on top. Some models have a separate display with a two-digit code.29 Used on: Professional Classic powered-vent models with the AP22511 Rev 02 chart and Rheem/Ruud models with a matching label or exact manual.

Bright and dim The heater is calling for heat. Safe to check yourself

Alternating bright and dim.

Next step: No service is needed for this normal pattern.30

1 flash every 3 seconds or 12 on the screen The control received a weak flame signal. Licensed technician only

1 flash every 3 seconds (screen shows 12).

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

1 flash, about every 4 seconds The tank is up to temperature and waiting. Safe to check yourself

Next step: No service is needed for this normal pattern.30

2 flashes or 44 on the screen The pressure switch stayed closed when it should have opened. Licensed technician only

2 flashes, pattern repeats about every 3 seconds (screen shows 44).

Likely cause: A blower pressure switch or wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

3 flashes or 46 on the screen The pressure switch or blower temperature switch stayed open. Licensed technician only

3 flashes, pattern repeats about every 3 seconds (screen shows 46).

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

4 flashes or 31 on the screen The tank reached its high temperature cutoff. Licensed technician only

4 flashes, pattern repeats about every 3 seconds (screen shows 31).

Likely cause: Tank temperature above the safety limit

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

5 flashes or 14 on the screen The control sensed a flame at the wrong time. Licensed technician only

Code 14 means the heater sensed a flame at the wrong time. The manual lists two light patterns for this screen code. Stop using the heater and call a licensed technician.

5 flashes, pattern repeats about every 3 seconds (screen shows 14).

Likely cause: A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

6 flashes, then 1 or 11 on the screen The heater shut down after a failed attempt to light. Licensed technician only

6 flashes, then 1 flash, pattern repeats about every 3 seconds (screen shows 11).

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

6 flashes, then 2 or 45 on the screen The heater shut down when a blower safety switch opened during operation. Licensed technician only

6 flashes, then 2 flashes, pattern repeats about every 3 seconds (screen shows 45).

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

6 flashes, then 3 or 13 on the screen The heater shut down after losing the flame. Licensed technician only

6 flashes, then 3 flashes, pattern repeats about every 3 seconds (screen shows 13).

Likely causes: Low gas supply pressure; A weak or faulty flame sensor; Restricted burner air

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

6 flashes, then 4 or 14 on the screen The heater shut down after sensing a flame at the wrong time. Licensed technician only

Code 14 means the heater sensed a flame at the wrong time. The manual lists two light patterns for this screen code. Stop using the heater and call a licensed technician.

6 flashes, then 4 flashes, pattern repeats about every 3 seconds (screen shows 14).

Likely cause: A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

6 flashes, then 5 or 10 on the screen The heater locked out after repeated attempts to light. Licensed technician only

6 flashes, then 5 flashes, pattern repeats about every 3 seconds (screen shows 10).

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

7 flashes or 47 on the screen Leave the area first The heater has locked out because the flammable-vapor sensor signaled danger.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

7 flashes, pattern repeats about every 3 seconds (screen shows 47).

Likely cause: Flammable vapors near the heater

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.30

8 flashes, then 1 or 49 on the screen Leave the area first The heater detected a fault in the flammable-vapor sensor circuit.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.9

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes, then 1 flash, pattern repeats about every 3 seconds (screen shows 49).

Likely cause: A faulty vapor sensor or gas control

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.30

8 flashes, then 2 or 89 on the screen The gas control detected a fault with its tank temperature readings. Licensed technician only

8 flashes, then 2 flashes, pattern repeats about every 3 seconds (screen shows 89).

Likely cause: A bad temperature probe or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

8 flashes, then 3 or 15 on the screen The gas control detected an electronics fault. Licensed technician only

8 flashes, then 3 flashes, pattern repeats about every 3 seconds (screen shows 15).

Likely cause: A faulty control module or temperature probe

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

8 flashes, then 4 or 93 on the screen The controller detected a gas valve fault. Licensed technician only

8 flashes, then 4 flashes, pattern repeats about every 3 seconds (screen shows 93).

Likely cause: A damaged or faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

Low-NOx standing-pilot gas valve with chamber sensor

Rectangular gas control at the bottom front.

Look for a round temperature and pilot dial on the left, a spark button below it and a small STATUS window to the right. The label lists blue for a normal single blink and red for faults. The printed guide adds 9 and 10 flashes. Match the heater's model and code legend because the face looks like the standard valve.31 Used on: Low-NOx tanks with the chamber-sensor chart in AP23699 or the same chart in their exact manual.

No light The gas control has no pilot power. Safe to check yourself

Likely causes: The knob is off; The pilot is out; The pilot is supplying too little power

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.32

Steady light The pilot was just shut off and the pilot power cell is cooling. Safe to check yourself

Red light: Steady light.

Likely cause: The gas control knob was turned to OFF

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.32

1 flash The heater is operating normally or is in pilot mode. Safe to check yourself

Blue light: 1 flash every 3 seconds.

Next step: No service is needed for this normal pattern.32

2 flashes The pilot is lit but is supplying too little power to the gas control. Licensed technician only

Red light: 2 flashes, pattern repeats about every 3 seconds.

Likely causes: A weak pilot; A damaged pilot power cell (thermopile) or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

4 flashes The heater shut down because tank water reached the high temperature limit. Licensed technician only

Red light: 4 flashes, pattern repeats about every 3 seconds.

Likely cause: Water above the high temperature limit

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

5 flashes The gas control detected a problem with its water temperature sensor. Licensed technician only

Red light: 5 flashes, pattern repeats about every 3 seconds.

Likely cause: A failing temperature sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

7 flashes The gas valve or its control has failed. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.9

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Red light: 7 flashes, pattern repeats about every 3 seconds.

Likely cause: A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

8 flashes The control picked up a pilot flame signal at the wrong time. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.9

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Red light: 8 flashes, pattern repeats about every 3 seconds.

Likely cause: A faulty pilot flame signal

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

9 flashes The burner chamber sensor has a fault. Licensed technician only

Red light: 9 flashes, pattern repeats about every 3 seconds.

Likely cause: A faulty chamber sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

10 flashes The heater shut down because the burner chamber reached its temperature limit. Licensed technician only

Red light: 10 flashes, pattern repeats about every 3 seconds.

Likely cause: Excessive burner chamber temperature

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

Ruud Low-NOx powered gas control

Low front valve with a round LOW to HOT temperature knob, separate ON/OFF switch and one status light.

Look for a cord and a powered blower at the vent on top. Some models have a separate display with a two-digit code. Match the AP19361 legend. It adds a chamber sensor pattern at nine flashes.33 Used on: Ruud Professional Achiever low-NOx models whose listed manual is AP19361. Match the rating plate and operating label.

Bright and dim The heater is calling for heat. Safe to check yourself

Alternating bright and dim.

Next step: No service is needed for this normal pattern.34

1 flash every 3 seconds The control received a weak flame signal. Licensed technician only

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

1 flash, about every 4 seconds The tank is up to temperature and waiting. Safe to check yourself

Next step: No service is needed for this normal pattern.34

2 flashes The pressure switch stayed closed when it should have opened. Licensed technician only

2 flashes, then a 3-second pause.

Likely cause: A blower pressure switch or wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

3 flashes The pressure switch or blower temperature switch stayed open. Licensed technician only

3 flashes, then a 3-second pause.

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

4 flashes This manual lists this pattern for either a high temperature cutoff or a flame detected at the wrong time. Licensed technician only

4 flashes, then a 3-second pause.

Likely causes: A faulty tank temperature probe or gas control; A pilot or burner valve stuck open

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

6 flashes, then 1 The heater shut down after a failed attempt to light. Licensed technician only

6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

6 flashes, then 2 The heater shut down when a blower safety switch opened during operation. Licensed technician only

6 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

6 flashes, then 3 The heater shut down after losing the flame. Licensed technician only

6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: Low gas supply pressure; A weak or faulty flame sensor; Restricted burner air

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

6 flashes, then 4 The heater shut down after sensing a flame at the wrong time. Licensed technician only

6 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

7 flashes Leave the area first The heater has locked out because the flammable-vapor sensor signaled danger.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

7 flashes, then a 3-second pause.

Likely causes: Flammable vapors near the heater; A faulty vapor sensor

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.34

8 flashes, then 1 Leave the area first The heater detected a fault in the flammable-vapor sensor circuit.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.9

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes, then 1 flash, then a 3-second pause.

Likely cause: A faulty vapor sensor or gas control

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.34

8 flashes, then 2 The gas control detected a fault with its tank temperature readings. Licensed technician only

8 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A bad temperature probe or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

8 flashes, then 3 The gas control detected an electronics fault. Licensed technician only

8 flashes, then 3 flashes, then a 3-second pause.

Likely cause: A faulty control module or temperature probe

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

8 flashes, then 4 The controller detected a gas valve fault. Licensed technician only

8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A damaged or faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

9 flashes The gas control detected a burner chamber sensor fault. Licensed technician only

9 flashes, then a 3-second pause.

Likely cause: A disconnected or failing chamber sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

9 flashes, then 2 The control detected a problem with the burner chamber temperature and air supply. Licensed technician only

9 flashes, then 2 flashes, then a 3-second pause.

Likely cause: Restricted combustion air

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.34

Not sure which control?

Look up a pattern on every control
No light The gas control has no pilot power. Safe to check yourself
Steady light The pilot was just shut off and the pilot power cell is cooling. Safe to check yourself
Bright and dim The heater is calling for heat. Safe to check yourself
1 flash Depends on the control

A slow single blue blink can be normal on a standing-pilot valve. On powered controls a single blink every three seconds reports a weak flame signal. Record the interval.

2 flashes Depends on the control

Low pilot power on a standing-pilot unit, a pressure switch fault on a powered vent, or a damper switch fault.

3 flashes Depends on the control

An open pressure switch on power vent or an open vent damper switch. Match the vent hardware.

4 flashes Depends on the control

Four flashes can indicate a temperature cutoff. Ruud AP19361 also assigns it to an out-of-sequence flame signal.

5 flashes Depends on the control

Temperature sensor fault on standing-pilot units. Flame at the wrong time on many powered units. On AP15756 powered damper it means the heater did not detect a flame.

Code 14 means the heater sensed a flame at the wrong time. The manual lists two light patterns for this screen code. Stop using the heater and call a licensed technician.

6 flashes, then 1 Depends on the control

Record both flash groups. Six followed by two can point to a blower safety switch or a damper switch.

6 flashes, then 2 Depends on the control

Record both flash groups. Six followed by two can point to a blower safety switch or a damper switch.

6 flashes, then 3 The heater shut down after losing the flame. Licensed technician only

Record both flash groups. Six followed by two can point to a blower safety switch or a damper switch.

6 flashes, then 4 The heater shut down after sensing a flame at the wrong time. Licensed technician only

Record both flash groups. Six followed by two can point to a blower safety switch or a damper switch.

Code 14 means the heater sensed a flame at the wrong time. The manual lists two light patterns for this screen code. Stop using the heater and call a licensed technician.

6 flashes, then 5 The heater locked out after repeated attempts to light. Licensed technician only

Record both flash groups. Six followed by two can point to a blower safety switch or a damper switch.

7 flashes Could this be a flammable vapor warning? Leave now Depends on the control

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.9

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Seven red flashes on the blue/red standing-pilot controller mean gas valve failure. Seven flashes on Honeywell Power Vent mean flammable-vapor lockout. Match the blower and model.

8 flashes Could this be a flammable vapor warning? Leave now The control picked up a pilot flame signal at the wrong time. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.9

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes alone and 8 flashes followed by a second group mean different things. Write down both groups if there is a second one.

8 flashes, then 1 Leave the area first The heater detected a fault in the flammable-vapor sensor circuit.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.9

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes alone and 8 flashes followed by a second group mean different things. Write down both groups if there is a second one.

8 flashes, then 2 Depends on the control

8 flashes alone and 8 flashes followed by a second group mean different things. Write down both groups if there is a second one.

8 flashes, then 3 The gas control detected an electronics fault. Licensed technician only

8 flashes alone and 8 flashes followed by a second group mean different things. Write down both groups if there is a second one.

8 flashes, then 4 The controller detected a gas valve fault. Licensed technician only

8 flashes alone and 8 flashes followed by a second group mean different things. Write down both groups if there is a second one.

9 flashes Depends on the control

Nine red flashes on the Low-NOx standing-pilot valve indicate a chamber sensor fault. AP19361 also uses nine followed by two for a chamber temperature or airflow fault.

9 flashes, then 2 The control detected a problem with the burner chamber temperature and air supply. Licensed technician only

Nine red flashes on the Low-NOx standing-pilot valve indicate a chamber sensor fault. AP19361 also uses nine followed by two for a chamber temperature or airflow fault.

10 flashes The heater shut down because the burner chamber reached its temperature limit. Licensed technician only
All lights flicker All six lights flickering erratically points to an unreliable or disconnected neutral connection. Licensed technician only
Lights 1 and 3 on The air-pressure switch stayed closed after a call for heat began. Licensed technician only
Lights 1 and 4 on The control cannot detect a proper electrical ground. Licensed technician only
Lights 1 and 5 on The heater sensed a flame at the wrong time. Licensed technician only
Lights 1 and 6 on Leave the area first The heater locked out after detecting flammable vapors.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2
Lights 1, 3 and 4 on The control thinks a temperature button is stuck. Licensed technician only

The Rheem bulletin prints a stuck button and a temperature sensor fault with these same lights. The Ruud guide lists only a stuck button here.

Rheem’s guide lists these same lights for two different faults. Call a licensed technician either way.

Lights 1, 3 and 5 on The control detected a problem with its electrical supply wiring. Licensed technician only
Lights 1, 3 and 6 on The air-pressure switch stayed open after the fan started. Licensed technician only
Lights 1, 4 and 5 on The burner failed to light or stay lit after several tries. Licensed technician only
Lights 1, 4 and 6 on Leave the area first The control detected a fault in the flammable-vapor sensor circuit.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.9

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2
Lights 1, 5 and 6 on The controller detected a fault in its gas valve drive circuit. Licensed technician only
Lights 1, 3, 4 and 5 on The controller detected a fault in its internal processor. Licensed technician only
Lights 1, 3, 4 and 6 on The tank temperature sensor circuit has a fault. Licensed technician only
Lights 1, 3, 5 and 6 on The controller detected a fault in the electric igniter circuit. Licensed technician only
Lights 1, 4, 5 and 6 on The tank reached the high temperature cutoff. Licensed technician only
Lights 1, 2, 3, 4, 5 and 6 on The controller detected a fault in an internal circuit. Licensed technician only
91 The optional display lost touch with the gas valve control. Licensed technician only

No status light: Mechanical standing-pilot gas valve. This mechanical valve has no status light. Use the model's printed guide for a pilot or heating problem.

How old is your heater?

Sources

37 numbered notes from 20 documents
  1. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveA. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765↑
  2. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
  3. U.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
  4. Technical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, pages 2, 7. 2018-02-07U.S. Fire Administration: Home Fire Escape Plans↑
  5. A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 25. 100307779 / 2000560245 Rev. BSupports the scald hazard. The manual also describes turning off the gas supply during a large discharge. This site says to keep clear and leave instead, because the valves are next to the scalding water.A. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveSupports hazard. Evacuation and 911 escalation follow the project safety tier.Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 42. U334-0773(00)↑
  6. A. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Supports hazard and ignition precautions. Evacuation follows the project safety tier.Pacific Gas and Electric Company: Gas Safety↑
  7. Rheem Manufacturing Company: Residential atmospheric FVIR gas water heater use and care manual, pages 1, 17, 24. AP23060 Rev 01↑
  8. Rheem Manufacturing Company: Residential atmospheric FVIR gas water heater use and care manual, page 24. AP23060 Rev 01↑
  9. A. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Seven flashes is the vapor sensor lockout; eight then one is a sensor fault. The two need the full pattern to tell apart.Rheem Manufacturing Company: Professional Classic Power Vent gas water heater use and care manual, page 37. AP22511 Rev 02Seven flashes and eight-then-one are both vapor sensor outcomes.Eight-then-one is the vapor sensor fault, seven flashes the vapor lockout.Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 5. TB 1621Separates a sensor circuit fault from vapor detection. Escalation for unresolved patterns follows docs/facts.md.Separates a sensor circuit fault from vapor detection. Evacuation for a sensor fault follows the project safety tier.Pacific Gas and Electric Company: Gas Safety↑
  10. Rheem Manufacturing Company: Technical Service Bulletin 1627, PowerVent ESII with Honeywell electronic control, pages 1, 2. TB 1627Rheem Manufacturing Company: Professional Classic Power Vent gas water heater use and care manual, page 27. AP22511 Rev 02↑
  11. Rheem Manufacturing Company: Technical Service Bulletin 1627, PowerVent ESII with Honeywell electronic control, page 1. TB 1627↑
  12. Rheem Manufacturing Company: Technical Service Bulletin 1627, PowerVent ESII with Honeywell electronic control, pages 1, 3. TB 1627↑
  13. Rheem Manufacturing Company: Technical Service Bulletin 1627, PowerVent ESII with Honeywell electronic control, pages 1, 2. TB 1627↑
  14. Rheem Manufacturing Company: Technical Service Bulletin 1627, PowerVent ESII with Honeywell electronic control, pages 1, 6. TB 1627↑
  15. Rheem Manufacturing Company: Technical Service Bulletin 1627, PowerVent ESII with Honeywell electronic control, page 7. TB 1627↑
  16. Rheem Manufacturing Company: Residential gas induced draft FVIR water heater use and care manual, pages 1, 9, 28. AP15696-3, 03/17↑
  17. Rheem Manufacturing Company: Residential gas induced draft FVIR water heater use and care manual, page 28. AP15696-3, 03/17↑
  18. Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 1. TB 1621Rheem Manufacturing Company: Ruud Professional Achiever Power Vent use and care manual, pages 1, 32. AP15762, 04/10↑
  19. Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 6. TB 1621↑
  20. Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 1. TB 1621Rheem Manufacturing Company: Ruud Professional Achiever Power Vent use and care manual, page 32. AP15762, 04/10↑
  21. Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 4. TB 1621Rheem Manufacturing Company: Ruud Professional Achiever Power Vent use and care manual, page 32. AP15762, 04/10↑
  22. Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 5. TB 1621Rheem Manufacturing Company: Ruud Professional Achiever Power Vent use and care manual, page 32. AP15762, 04/10↑
  23. Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 2. TB 1621Rheem Manufacturing Company: Ruud Professional Achiever Power Vent use and care manual, page 32. AP15762, 04/10↑
  24. Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 3. TB 1621Rheem Manufacturing Company: Ruud Professional Achiever Power Vent use and care manual, page 32. AP15762, 04/10↑
  25. Rheem Manufacturing Company: Ruud Professional Achiever Power Vent use and care manual, page 32. AP15762, 04/10↑
  26. Rheem Manufacturing Company: Residential gas water heater with damper and electronic control use and care manual, pages 1, 18, 24. AP15756, 05/10↑
  27. Rheem Manufacturing Company: Residential gas water heater with damper and electronic control use and care manual, page 24. AP15756, 05/10↑
  28. Rheem Manufacturing Company: Residential gas water heater with damper and electronic control use and care manual, page 25. AP15756, 05/10↑
  29. Rheem Manufacturing Company: Professional Classic Power Vent gas water heater use and care manual, pages 1, 27, 28, 37. AP22511 Rev 02↑
  30. Rheem Manufacturing Company: Professional Classic Power Vent gas water heater use and care manual, page 37. AP22511 Rev 02↑
  31. Rheem Manufacturing Company: Residential low-NOx gas water heater use and care manual, chamber sensor chart, pages 1, 17, 24. AP23699↑
  32. Rheem Manufacturing Company: Residential low-NOx gas water heater use and care manual, chamber sensor chart, page 24. AP23699↑
  33. Rheem Manufacturing Company: Ruud Professional Achiever Ultra Low NOx gas water heater with electronic control, pages 1, 32. AP19361, 12/17↑
  34. Rheem Manufacturing Company: Ruud Professional Achiever Ultra Low NOx gas water heater with electronic control, page 32. AP19361, 12/17↑
  35. A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 24. 100307779 / 2000560245 Rev. BA. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 14. 325321-000Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 53. U334-0773(00)Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape Plans
  36. Rheem Manufacturing Company: Technical Service Bulletin 1425, White-Rodgers atmospheric thermostat control, page 1. TB 1425
  37. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveTechnical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, page 2. 2018-02-07Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 54. U334-0773(00)

Facts checked November 27, 2026, against documents retrieved November 27, 2026. Independent site, not affiliated with Rheem or Ruud. Your heater’s manual and label are the final word. In an emergency, get everyone outside first and call 911 from a safe spot outside. How we check facts