Water heater making a popping noise
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
- 1. Get everyone outside and well away from the building now.
- 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
- 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2
Carbon monoxide alarm? Get outside
Get everyone to fresh air outside right away and call 911. Stay outside until emergency responders say it is safe to go back in.3
Flames coming out of the heater, smoke, or burn marks or melted parts that might be new? Get outside
If you see flames coming out of the heater, smoke, or signs it may still be burning, get everyone out and call 911 from outside. Leave the heater and switches alone. If you find unexplained burn marks or melted parts and can’t tell whether there’s an active fire, get outside and call 911. If you know the damage is old and there are no other emergency signs, keep the heater out of use and call a licensed technician.4
Water gushing or spraying from the safety valve’s pipe, or hot spray or steam near the heater? Leave now
The relief pipe is the pipe from the heater’s pressure safety valve. Keep clear of the heater, pipe and valves, even if you can’t tell where hot spray is coming from. Leave by a safe route and call 911 from outside. A slow drip without steam or other warning signs calls for safe shutoff and a plumber.5
Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
Standing water near the heater, wet electrical equipment, or water near wiring or a breaker panel? Stay back. Stay out of the water and skip the checks below.
If you can reach your home’s main water shutoff from a dry spot without going near the water, close it and call for help. Call a licensed electrician for wet electrical equipment. Have a qualified technician check a flooded heater before using it again.7
If none of those apply: first steps
-
Read any code on the outside
The noise is the only symptom and you can safely see a display or light.
If it is safe to look, note the exact letters or numbers on the screen, or the color and number of flashes. Leave the covers and controls alone.8
Safe to check yourself
-
Look for where the water starts
The heater was fully shut off for a leak and no water is near electrical equipment.
Only after the water and every power or gas shutoff in the manual are off, and no water is near wiring, a plug or the breaker panel: look from a dry spot for the highest wet point you can see. A front OFF button alone does not count as shutoff. Water can run down the outside of the heater before it pools. Leave covers in place and keep clear of hot pipes.9
Shut off and check
-
Get help with gas, burner, or vent problems
There is a loud bang at gas burner startup, damage to the pilot window, or soot around the heater, with no stop-now condition.
Stop using the heater and call a licensed gas technician for a burner, gas control, or vent problem. Leave the burner cover in place and leave any relighting or resets to the technician.10
Licensed technician only
What usually causes it
-
Mineral buildup in a tank heater
Pops, crackles, or low rumbles repeat while the tank heats. Minerals can build up at the bottom of a tank or on an electric heating element. Sound alone cannot confirm the cause.11
Leave the repair to a plumber or technician
-
Condensation dripping as a cold gas tank starts to heat
You heard a brief sizzle during a cold start, and it stopped once the tank warmed up. Persistent noise or a growing puddle needs a closer look by a technician.12
Safe to check yourself from a dry spot
-
An unusual reaction between the water and an aluminum anode rod
A new tank with an aluminum anode rod can crackle or gurgle in some areas. If you’ve already seen jelly-like material at a faucet, tell the technician.13
Leave the repair to a plumber or technician
-
Water hammer (a pressure jolt in the pipes)
A sharp bang comes from a pipe right when a faucet or appliance valve shuts off. You may hear it even when the heater isn’t running.14
Leave the repair to a plumber or technician
-
A gas burner or vent problem
There is a loud bang as the gas burner starts, or soot appears around the heater. Flames coming out of the heater, smoke, burn marks or melted parts that might be new, or a carbon monoxide alarm call for the stop-now steps.15
Leave the repair to a plumber or technician
Check the official recall notice
Once everyone is safe, compare your model and serial number with the official recall notice. If your heater is included, follow its safety directions and use any free remedy it offers before paying for repair or replacement.16
Repair or replace?
A plumber can check whether service for mineral buildup or a faulty part makes sense. Noise alone tells you little about whether to replace the heater. A confirmed leak through the tank itself means replacement.17
Check how old your heater is, how long water heaters last, and what a replacement costs.
Related
Sources
17 numbered notes from 19 documents
- Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveA. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765↑
- Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
- U.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
- Technical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, pages 2, 7. 2018-02-07U.S. Fire Administration: Home Fire Escape Plans↑
- A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 25. 100307779 / 2000560245 Rev. BSupports the scald hazard. The manual also describes turning off the gas supply during a large discharge. This site says to keep clear and leave instead, because the valves are next to the scalding water.A. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveSupports hazard. Evacuation and 911 escalation follow the project safety tier.Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 42. U334-0773(00)↑
- A. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Supports hazard and ignition precautions. Evacuation follows the project safety tier.Pacific Gas and Electric Company: Gas Safety↑
- Centers for Disease Control and Prevention: Safety Guidelines: Reentering Your Flooded HomeU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
- Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 54. U334-0773(00)A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 24. 100307779 / 2000560245 Rev. B↑
- A. O. Smith: Residential Electric Water Heaters, Models 6–120, page 19. 185762-002A. O. Smith: Bulletin 51: Puddle on FloorCenters for Disease Control and Prevention: Safety Guidelines: Reentering Your Flooded Home↑
- A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 24. 100307779 / 2000560245 Rev. BA. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 14. 325321-000Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 53. U334-0773(00)↑
- A. O. Smith: Bulletin 13: Mineral Build-UpBradford White: Internal NoisesA. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 16. 325321-000↑
- A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 23. 100307779 / 2000560245 Rev. BA. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 16. 325321-000↑
- A. O. Smith: Bulletin 14: Aluminum Hydroxide↑
- A. O. Smith: Water Heater Repair: Things to Consider↑
- A. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 14. 325321-000Technical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, page 2. 2018-02-07A. O. Smith: Hot Water Heating Making Noises↑
- U.S. Consumer Product Safety Commission: Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards↑
- A. O. Smith: Bulletin 13: Mineral Build-UpA. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 16. 325321-000A. O. Smith: Bulletin 51: Puddle on Floor↑
Facts checked November 27, 2026, against documents retrieved November 27, 2026. General information, not a diagnosis: if you are unsure, stop and call a licensed plumber or technician. Your heater’s manual and the official recall notice are the final word on your model. In an emergency, get everyone outside first and call 911 from a safe spot outside. How we check facts