Water heater drain valve leaking
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
- 1. Get everyone outside and well away from the building now.
- 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
- 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2
Carbon monoxide alarm? Get outside
Get everyone to fresh air outside right away and call 911. Stay outside until emergency responders say it is safe to go back in.3
Flames coming out of the heater, smoke, or burn marks or melted parts that might be new? Get outside
If you see flames coming out of the heater, smoke, or signs it may still be burning, get everyone out and call 911 from outside. Leave the heater and switches alone. If you find unexplained burn marks or melted parts and can’t tell whether there’s an active fire, get outside and call 911. If you know the damage is old and there are no other emergency signs, keep the heater out of use and call a licensed technician.4
Water gushing or spraying from the safety valve’s pipe, or hot spray or steam near the heater? Leave now
The relief pipe is the pipe from the heater’s pressure safety valve. Keep clear of the heater, pipe and valves, even if you can’t tell where hot spray is coming from. Leave by a safe route and call 911 from outside. A slow drip without steam or other warning signs calls for safe shutoff and a plumber.5
Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
Standing water near the heater, wet electrical equipment, or water near wiring or a breaker panel? Stay back. Stay out of the water and skip the checks below.
If you can reach your home’s main water shutoff from a dry spot without going near the water, close it and call for help. Call a licensed electrician for wet electrical equipment. Have a qualified technician check a flooded heater before using it again.7
If none of those apply: first steps
-
Shut off the cold water
No stop-now condition applies and you can reach a water shutoff safely.
- 1. From a dry spot, find the valve on the cold water pipe going into the heater. Look for a COLD or C label on the water inlet. Keep clear of hot water and steam.
- 2. Turn a lever a quarter turn so it sits across the pipe, or turn a round handle to the right until it stops. Use only your hand.
- 3. If the valve is stuck, hard to reach, or unclear, use your home's main water shutoff if you know where it is and can reach it safely. Otherwise, call a licensed plumber.8
Shut off and check
-
Turn off the heater
There are no stop-now signs and no water near electrical equipment.
Use only the directions for your type. If you’re unsure which type you have or can’t safely reach every shutoff your manual names, stay back and call a licensed technician.9
Gas heater with a tank
Follow your exact model’s shutdown instructions. A gas control knob, a separate gas supply valve and an electrical shutoff may all be involved. If there is no gas odor or other emergency and you can reach a clearly marked gas control knob safely from a dry spot, turn it to OFF by hand. On a standing-pilot model, PILOT can leave a small flame lit. A gas tank with a power cord, a fan or other powered controls also has a power switch or plug. If you cannot safely reach every shutoff the manual names, the knob is stuck, or the controls look different, keep away and call a licensed gas technician.10
Gas tankless heater
A front OFF button may stop the heater while electricity and gas are still connected. For a dry heater with no emergency signs, use the shutdown instructions for your exact model. If you cannot safely identify or reach all the shutoffs the manual calls for, keep away and call a licensed gas technician.11
Electric heater, with or without a tank
With dry hands and a dry path to a dry breaker panel, switch the clearly labeled water heater breaker to OFF. If the heater has several labeled breakers, switch them all off. Leave the heater covers in place and skip this step if the panel is wet or you cannot identify the right breakers.12
Shut off and check
-
Never cap or plug the relief valve or its pipe
Leave the test lever alone. The temperature and pressure relief valve is a safety outlet for hot water under pressure, so never block it or the pipe attached to it.13
Shut off and check
-
Look for where the water starts
You finished the shutoff steps above and no water is near electrical equipment.
Only after the water and every power or gas shutoff in the manual are off, and no water is near wiring, a plug or the breaker panel: look from a dry spot for the highest wet point you can see. A front OFF button alone does not count as shutoff. Water can run down the outside of the heater before it pools. Leave covers in place and keep clear of hot pipes.14
Shut off and check
-
Catch a small, cool drip
You finished the shutoff steps above and a small, cool drip is within easy reach from a dry spot.
Only after the water and every power or gas shutoff in the manual are off, and no water is near wiring, a plug or the breaker panel: a shallow pan can catch a few cool drips if you can set it down from a dry spot. A front OFF button alone does not count as shutoff. Keep the pan clear of the relief pipe outlet and leave any installed drain path open. For hot, fast, or hard-to-reach leaks, stay back.15
Shut off and check
-
Leave the heater off after a leak
You shut the heater down for a leak.
Keep the heater off until the cause of the leak is fixed and the heater is safe to use. A tank heater must be full before heat goes back on.16
Shut off and check
Where is the water coming from?
These clues can help you describe what you already saw. If the heater is leaking, look again only after safe water and energy shutoff. Stay clear of wet electrical equipment and hot water.17
-
Drip at the drain valve spout
You already saw a drip form at the hose spout, sometimes after the tank was drained or flushed. Leave the leaking valve alone and tell the plumber where the drip started.18
Leave the repair to a plumber or technician
-
Leak where the drain valve meets the tank
Fresh water appears around the base of the valve where it screws into the tank. The spout tip may still be dry.19
Leave the repair to a plumber or technician
-
Water running down from higher up
A wet trail starts higher than the drain valve, or the puddle sits under the separate open pipe from the safety relief valve.18
Leave the repair to a plumber or technician
-
A cold pipe is sweating above the drain valve
Small beads cover part of the cold pipe and fall toward the valve. If a joint keeps dripping, treat it as a leak.19
Safe to check yourself from a dry spot
Check the official recall notice
Once everyone is safe, compare your model and serial number with the official recall notice. If your heater is included, follow its safety directions and use any free remedy it offers before paying for repair or replacement.20
Repair or replace?
A plumber can usually fix a leaking connection or replace a faulty drain valve. Leave draining to the plumber if this valve is already leaking. A leak through the tank itself means replacement.21
Check how old your heater is, how long water heaters last, and what a replacement costs.
Related
Sources
21 numbered notes from 18 documents
- Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveA. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765↑
- Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
- U.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
- Technical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, pages 2, 7. 2018-02-07U.S. Fire Administration: Home Fire Escape Plans↑
- A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 25. 100307779 / 2000560245 Rev. BSupports the scald hazard. The manual also describes turning off the gas supply during a large discharge. This site says to keep clear and leave instead, because the valves are next to the scalding water.A. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveSupports hazard. Evacuation and 911 escalation follow the project safety tier.Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 42. U334-0773(00)↑
- A. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Supports hazard and ignition precautions. Evacuation follows the project safety tier.Pacific Gas and Electric Company: Gas Safety↑
- Centers for Disease Control and Prevention: Safety Guidelines: Reentering Your Flooded HomeU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
- City of Hamilton, Ohio: Locating & Operating Water Shut-Off ValvesA. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 16. 100307779 / 2000560245 Rev. BA. O. Smith: How to Turn a Water Heater On & OffRinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 65. U334-0773(00)↑
- A. O. Smith: How to Turn a Water Heater On & OffA. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, pages 22, 27. 100307779 / 2000560245 Rev. BRinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 65. U334-0773(00)↑
- A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, pages 22, 27. 100307779 / 2000560245 Rev. BA. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Powered gas tank: power switch on the gas control and a power cord.Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 53. U334-0773(00)↑
- Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, pages 53, 54, 65. U334-0773(00)↑
- A. O. Smith: How to Turn a Water Heater On & OffA. O. Smith: Residential Electric Water Heaters, Models 6–120, page 12. 185762-002Centers for Disease Control and Prevention: Safety Guidelines: Reentering Your Flooded Home↑
- A. O. Smith: Residential Electric Water Heaters, Models 6–120, page 9. 185762-002A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 25. 100307779 / 2000560245 Rev. BRinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 42. U334-0773(00)↑
- A. O. Smith: Residential Electric Water Heaters, Models 6–120, page 19. 185762-002A. O. Smith: Bulletin 51: Puddle on FloorCenters for Disease Control and Prevention: Safety Guidelines: Reentering Your Flooded Home↑
- A. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 6. 325321-000A. O. Smith: Water Heater Repair: Things to ConsiderA. O. Smith: Residential Electric Water Heaters, Models 6–120, page 9. 185762-002Centers for Disease Control and Prevention: Safety Guidelines: Reentering Your Flooded Home↑
- A. O. Smith: How to Turn a Water Heater On & OffA. O. Smith: Residential Electric Water Heaters, Models 6–120, page 19. 185762-002A. O. Smith: Why Is My Water Heater Leaking?↑
- A. O. Smith: Residential Electric Water Heaters, Models 6–120, page 19. 185762-002Centers for Disease Control and Prevention: Safety Guidelines: Reentering Your Flooded Home↑
- A. O. Smith: Residential Electric Water Heaters, Models 6–120, page 19. 185762-002A. O. Smith: Bulletin 51: Puddle on Floor↑
- A. O. Smith: Residential Electric Water Heaters, Models 6–120, page 19. 185762-002↑
- U.S. Consumer Product Safety Commission: Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards↑
- A. O. Smith: Residential Electric Water Heaters, Models 6–120, page 19. 185762-002A. O. Smith: Bulletin 51: Puddle on FloorA. O. Smith: Why Is My Water Heater Leaking?↑
Facts checked November 27, 2026, against documents retrieved November 27, 2026. General information, not a diagnosis: if you are unsure, stop and call a licensed plumber or technician. Your heater’s manual and the official recall notice are the final word on your model. In an emergency, get everyone outside first and call 911 from a safe spot outside. How we check facts