Navien error codes

Type the code from the screen.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2
Carbon monoxide alarm? Get outside

Get everyone to fresh air outside right away and call 911. Stay outside until emergency responders say it is safe to go back in.3

Flames coming out of the heater, smoke, or burn marks or melted parts that might be new? Get outside

If you see flames coming out of the heater, smoke, or signs it may still be burning, get everyone out and call 911 from outside. Leave the heater and switches alone. If you find unexplained burn marks or melted parts and can’t tell whether there’s an active fire, get outside and call 911. If you know the damage is old and there are no other emergency signs, keep the heater out of use and call a licensed technician.4

Water gushing or spraying from the safety valve’s pipe, or hot spray or steam near the heater? Leave now

The relief pipe is the pipe from the heater’s pressure safety valve. Keep clear of the heater, pipe and valves, even if you can’t tell where hot spray is coming from. Leave by a safe route and call 911 from outside. A slow drip without steam or other warning signs calls for safe shutoff and a plumber.5

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Every code, by model

Legacy CH-ASME combi boiler

Look for the wired wall control with a rectangular screen above a round center dial.

DHW and Heating sit on either side of the dial, with Stand By, Program and ON/OFF below. Match CH and ASME on the appliance rating plate.7 Used on: CH-ASME combi boilers (home heating and tap water) in the operation manual.

E001 The control detected water boiling inside the heat exchanger. Licensed technician only
E002 Water pressure in the home-heating loop is too low. Licensed technician only
E003 The burner did not light. Licensed technician only
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E005 The space-heating supply temperature sensor circuit is open. Licensed technician only
E006 The space-heating supply temperature sensor circuit is shorted. Licensed technician only
E007 The hot water outlet temperature sensor circuit is open. Licensed technician only
E008 The hot water outlet temperature sensor circuit is shorted. Licensed technician only
E009 The heater detected a problem with its fan. Licensed technician only
E010 The heater detected abnormal air pressure. Licensed technician only
E011 Pressure in the home-heating loop is too high. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E013 The boiler detected a pump problem. Licensed technician only
E015 The heater detected a control board fault. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E018 The space-heating return temperature sensor circuit is open. Licensed technician only
E019 The space-heating return temperature sensor circuit is shorted. Licensed technician only
E021 The cold water inlet temperature sensor circuit is open. Licensed technician only
E022 The cold water inlet temperature sensor circuit is shorted. Licensed technician only
E027 The air pressure sensor reported a problem. Licensed technician only
E028 The boiler detected a leak in the home-heating loop. Shut off safely and call a plumber
E030 The heater shut down because the exhaust temperature was too high. Licensed technician only
E035 The gas pressure sensor reported a problem. Licensed technician only
E036 The heater detected a communication fault. Licensed technician only
E037 The heater detected water leaking inside the unit. Shut off safely and call a plumber
E039 The control detected a problem with the water flow sensor. Licensed technician only
E040 The outdoor temperature sensor circuit is shorted. Licensed technician only

NCB-E combi boiler

Dark narrow panel with a small rectangular display near the top, a flat grid of buttons and the Navien name near its base.

The display includes space heating and water pressure icons. Match the model ending in E.10 Used on: NCB-150E, 180E, 210E and 240E condensing combi boilers.

E003 The burner did not light. Licensed technician only
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E030 The boiler detected an abnormal exhaust temperature. Licensed technician only
E046 The heater detected a fault with its temperature safety circuit. Licensed technician only
E047 The exhaust temperature sensor circuit has a fault. Licensed technician only
E060 The heater detected a fault in the part that helps mix gas and air for the burner. Licensed technician only
E109 The heater detected a problem with the combustion fan. Licensed technician only
E110 The heater detected a problem with airflow through the air intake or exhaust. Licensed technician only
E205 The temperature sensor on the heating supply side reported a problem. Licensed technician only
E218 The temperature sensor on the heating return side reported a problem. Licensed technician only
E351 The valve that automatically adds water to the heating loop is reporting a fault. Licensed technician only
E352 The boiler detected high water pressure in the heating loop. Licensed technician only
E353 The water pressure sensor has a fault. Licensed technician only
E407 The primary hot water outlet temperature sensor circuit has a fault. Licensed technician only
E421 The primary cold water inlet temperature sensor circuit has a fault. Licensed technician only
E439 The heater reported a problem with its water flow sensor. Licensed technician only
E515 The heater detected a problem with its main circuit board. Licensed technician only
E517 The heater found a problem with its internal setup switch settings. Licensed technician only
E594 The control detected a fault in the chip that stores its settings. Licensed technician only
E615 The control detected a fault with its input signals or memory. Licensed technician only
E736 The linked units are having trouble communicating with each other. Licensed technician only
E740 The heater cannot get a reliable reading from the outdoor temperature sensor. Licensed technician only
E777 The boiler detected a problem with its low-water cutoff. Licensed technician only
E782 The display panel and main control are having trouble communicating. Licensed technician only

NCB-H combi boiler

Dark panel with a wide icon display, three small buttons in a row below it and a large round command dial near the bottom.

Match NCB and the final H in the model number on the rating plate.12 Used on: NCB-H condensing combi boilers covered by the February 2024 installation manual and January 2025 user's manual.

E001 The heat exchanger got too hot. Licensed technician only
E003 The burner did not light. Licensed technician only
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E020 The boiler reports a problem with its gas control valve. Licensed technician only
E030 The boiler detected an exhaust temperature that was too high. Licensed technician only
E031 The heater detected burner overheating. Licensed technician only
E046 The heat exchanger temperature sensor has a fault. Licensed technician only
E047 The exhaust temperature sensor circuit has a fault. Licensed technician only
E060 The heater detected a fault in the part that helps mix gas and air for the burner. Licensed technician only
E109 The heater detected a problem with the combustion fan. Licensed technician only
E110 The boiler detected a blocked exhaust. Licensed technician only
E123 The boiler detected a blower fault. Licensed technician only
E205 The temperature sensor on the heating supply side reported a problem. Licensed technician only
E218 The temperature sensor on the heating return side reported a problem. Licensed technician only
E278 The boiler cannot read the external heating supply temperature sensor. Licensed technician only
E279 The boiler cannot read the external heating return temperature sensor. Licensed technician only
E351 The valve that automatically adds water to the heating loop is reporting a fault. Licensed technician only
E352 The boiler detected high water pressure in the heating loop. Licensed technician only
E353 The water pressure sensor has a fault. Licensed technician only
E407 The primary hot water outlet temperature sensor circuit has a fault. Licensed technician only
E421 The primary cold water inlet temperature sensor circuit has a fault. Licensed technician only
E434 The valve that adjusts water flow is reporting a fault. Licensed technician only
E439 The boiler did not detect hot water flow. Licensed technician only
E441 The second hot water outlet temperature sensor has a fault. Licensed technician only
E445 The internal mixing valve reported a fault. Licensed technician only
E515 The heater detected a problem with its main circuit board. Licensed technician only
E517 The heater found a problem with its internal setup switch settings. Licensed technician only
E594 The control detected a fault in the chip that stores its settings. Licensed technician only
E615 The control detected a memory fault. Licensed technician only
E736 The linked units are having trouble communicating with each other. Licensed technician only
E740 The boiler could not detect the outdoor temperature sensor. Licensed technician only
E761 The boiler cannot detect the temperature switch for the preheat pump. Licensed technician only
E762 The heater detected that the exhaust pipe is not fully seated. Licensed technician only
E773 The heater detected the wrong fuel type. Licensed technician only
E777 The boiler activated its low-water safety cutoff. Licensed technician only
E782 The display panel and main control are having trouble communicating. Licensed technician only
E784 The boiler is having trouble communicating with the controller for its heating zones. Licensed technician only
E786 The boiler detected the wrong front panel for this model. Licensed technician only
E788 The control detected an incorrect fuel type setting. Licensed technician only

NCB700 combi boiler

Dark panel with a wide icon display, three small buttons in a row below it and a large round command dial near the bottom.

Match NCB700 on the rating plate. The control layout is similar to the NCB-H.16 Used on: NCB700 condensing combi boilers listed in the July 2026 installation and operation manual.

E001 The heat exchanger got too hot. Licensed technician only
E003 The burner did not light. Licensed technician only
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E020 The boiler reports a problem with its gas control valve. Licensed technician only
E030 The boiler detected an exhaust temperature that was too high. Licensed technician only
E046 The heat exchanger temperature sensor has a fault. Licensed technician only
E047 The exhaust temperature sensor circuit has a fault. Licensed technician only
E060 The heater detected a fault in the part that helps mix gas and air for the burner. Licensed technician only
E109 The heater detected a problem with the combustion fan. Licensed technician only
E110 The boiler detected a blocked exhaust. Licensed technician only
E123 The boiler detected a blower fault. Licensed technician only
E205 The temperature sensor on the heating supply side reported a problem. Licensed technician only
E218 The temperature sensor on the heating return side reported a problem. Licensed technician only
E278 The boiler cannot read the external heating supply temperature sensor. Licensed technician only
E279 The boiler cannot read the external heating return temperature sensor. Licensed technician only
E302 The boiler detected low water pressure in the heating loop. Licensed technician only
E352 The boiler detected high water pressure in the heating loop. Licensed technician only
E353 The water pressure sensor has a fault. Licensed technician only
E407 The primary hot water outlet temperature sensor circuit has a fault. Licensed technician only
E421 The primary cold water inlet temperature sensor circuit has a fault. Licensed technician only
E434 The valve that adjusts water flow is reporting a fault. Licensed technician only
E439 The boiler did not detect hot water flow. Licensed technician only
E441 The second hot water outlet temperature sensor has a fault. Licensed technician only
E445 The internal mixing valve reported a fault. Licensed technician only
E515 The heater detected a problem with its main circuit board. Licensed technician only
E517 The heater found a problem with its internal setup switch settings. Licensed technician only
E593 The control detected a problem with a front panel button. Licensed technician only
E594 The control detected a fault in the chip that stores its settings. Licensed technician only
E598 The control reported a problem communicating with its internal clock. Licensed technician only
E615 The control detected a memory fault. Licensed technician only
E736 The linked units are having trouble communicating with each other. Licensed technician only
E740 The boiler could not detect the outdoor temperature sensor. Licensed technician only
E761 The boiler cannot detect the temperature switch for the preheat pump. Licensed technician only
E762 The heater detected that the exhaust pipe is not fully seated. Licensed technician only
E773 The heater detected the wrong fuel type. Licensed technician only
E777 The boiler activated its low-water safety cutoff. Licensed technician only
E782 The display panel and main control are having trouble communicating. Licensed technician only
E784 The boiler is having trouble communicating with the controller for its heating zones. Licensed technician only
E786 The boiler detected the wrong front panel for this model. Licensed technician only
E788 The control detected an incorrect fuel type setting. Licensed technician only

NFC-H combi boiler

Dark panel with a wide icon display, three small buttons in a row below it and a large round command dial near the bottom.

Confirm NFC-250/175H or NFC-250/200H on the rating plate. The front panel resembles the NCB-H panel.19 Used on: NFC-250/175H and NFC-250/200H condensing combi boilers.

E001 The heat exchanger got too hot. Licensed technician only
E003 The burner did not light. Licensed technician only
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E030 The boiler detected an exhaust temperature that was too high. Licensed technician only
E031 The heater detected burner overheating. Licensed technician only
E046 The heat exchanger temperature sensor has a fault. Licensed technician only
E047 The exhaust temperature sensor circuit has a fault. Licensed technician only
E060 The heater detected a fault in the part that helps mix gas and air for the burner. Licensed technician only
E109 The heater detected a problem with the combustion fan. Licensed technician only
E110 The boiler detected a blocked exhaust. Licensed technician only
E205 The temperature sensor on the heating supply side reported a problem. Licensed technician only
E218 The temperature sensor on the heating return side reported a problem. Licensed technician only
E278 The boiler cannot read the external heating supply temperature sensor. Licensed technician only
E279 The boiler cannot read the external heating return temperature sensor. Licensed technician only
E351 The valve that automatically adds water to the heating loop is reporting a fault. Licensed technician only
E352 The boiler detected high water pressure in the heating loop. Licensed technician only
E353 The water pressure sensor has a fault. Licensed technician only
E407 The primary hot water outlet temperature sensor circuit has a fault. Licensed technician only
E421 The primary cold water inlet temperature sensor circuit has a fault. Licensed technician only
E434 The valve that adjusts water flow is reporting a fault. Licensed technician only
E439 The boiler did not detect hot water flow. Licensed technician only
E441 The second hot water outlet temperature sensor has a fault. Licensed technician only
E445 The internal mixing valve reported a fault. Licensed technician only
E515 The heater detected a problem with its main circuit board. Licensed technician only
E517 The heater found a problem with its internal setup switch settings. Licensed technician only
E594 The control detected a fault in the chip that stores its settings. Licensed technician only
E615 The control detected a memory fault. Licensed technician only
E736 The linked units are having trouble communicating with each other. Licensed technician only
E740 The boiler could not detect the outdoor temperature sensor. Licensed technician only
E761 The boiler cannot detect the temperature switch for the preheat pump. Licensed technician only
E762 The heater detected that the exhaust pipe is not fully seated. Licensed technician only
E773 The heater detected the wrong fuel type. Licensed technician only
E777 The boiler activated its low-water safety cutoff. Licensed technician only
E782 The display panel and main control are having trouble communicating. Licensed technician only
E784 The boiler is having trouble communicating with the controller for its heating zones. Licensed technician only
E786 The boiler detected the wrong front panel for this model. Licensed technician only
E788 The control detected an incorrect fuel type setting. Licensed technician only
E

NHW700 non-condensing tankless

Indoor and universal units have a tall, dark, tapered panel with the Navien name below the buttons.

Diagnostics, information and reset are on the left and plus, minus and power are on the right. Use an installed remote on exterior models and confirm NHW700 from the rating plate.22 Used on: NHW700 interior, universal and exterior non-condensing units in the cited installation manual. Lists only the codes published in Navien’s public installation guide.

E762 The heater detected a problem with how the exhaust vent pipe fits. Licensed technician only
E773 The heater detected a possible mismatch between the fuel supplied and its setup. Licensed technician only
E

Original NPE-A / NPE-S

Dark narrow front panel with a rectangular number display at the top.

Below it are diagnostics, information and reset controls on the left, and plus, minus and power on the right. The Navien name is above the screen. Check for A or S on the rating plate.25 Used on: Original NPE-A and NPE-S condensing tankless models listed in the operation manual.

E003 The burner did not light. Licensed technician only
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E030 The heater shut down because the exhaust temperature was too high. Licensed technician only
E046 The heater detected a fault with its temperature safety circuit. Licensed technician only
E047 The exhaust temperature sensor circuit has a fault. Licensed technician only
E060 The heater detected a fault in the part that helps mix gas and air for the burner. Licensed technician only
E109 The heater detected a problem with the combustion fan. Licensed technician only
E110 The heater detected a problem with airflow through the air intake or exhaust. Licensed technician only
E407 The primary hot water outlet temperature sensor circuit has a fault. Licensed technician only
E421 The primary cold water inlet temperature sensor circuit has a fault. Licensed technician only
E432 The second cold water inlet temperature sensor circuit has a fault. Licensed technician only
E434 The valve that adjusts water flow is reporting a fault. Licensed technician only
E438 The heater reported a problem with the circulation pump. Licensed technician only
E439 The heater reported a problem with its water flow sensor. Licensed technician only
E441 The second hot-water inlet temperature sensor circuit is open or shorted. Licensed technician only
E445 The internal bypass mixing valve reported a fault. Licensed technician only
E515 The heater detected a problem with its main circuit board. Licensed technician only
E517 The heater found a problem with its internal setup switch settings. Licensed technician only
E593 The control detected a problem with a front panel button. Licensed technician only
E615 The control detected a fault with its input signals or memory. Licensed technician only
E736 The linked units are having trouble communicating with each other. Licensed technician only
E740 The heater cannot get a reliable reading from the outdoor temperature sensor. Licensed technician only
E760 The heater is signaling that routine service is due. Safe to check yourself
E782 The display panel and main control are having trouble communicating. Licensed technician only
E785 The flow switch or flow sensor reported a problem. Licensed technician only
E

NPE-A2 / NPE-S2

Tall dark panel with a small rectangular display above two columns of buttons.

M, back arrow and OK are on the left. Up, down and power are on the right. Match a model ending in A2 or S2 on the rating plate.27 Used on: NPE-2 condensing tankless water heaters, including the -180, -210 and -240 variants where listed.

E003 The burner did not light. Licensed technician only
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E030 The heater shut down because the exhaust temperature was too high. Licensed technician only
E031 The heater detected burner overheating. Licensed technician only
E046 The heater detected a fault with its temperature safety circuit. Licensed technician only
E047 The exhaust temperature sensor circuit has a fault. Licensed technician only
E060 The heater detected a fault in the part that helps mix gas and air for the burner. Licensed technician only
E109 The heater detected a problem with the combustion fan. Licensed technician only
E110 The heater detected a problem with airflow through the air intake or exhaust. Licensed technician only
E407 The primary hot water outlet temperature sensor circuit has a fault. Licensed technician only
E421 The primary cold water inlet temperature sensor circuit has a fault. Licensed technician only
E432 The second cold water inlet temperature sensor circuit has a fault. Licensed technician only
E434 The valve that adjusts water flow is reporting a fault. Licensed technician only
E438 The heater reported a problem with the circulation pump. Licensed technician only
E439 The heater reported a problem with its water flow sensor. Licensed technician only
E441 The second hot-water inlet temperature sensor circuit is open or shorted. Licensed technician only
E445 The internal bypass mixing valve reported a fault. Licensed technician only
E515 The heater detected a problem with its main circuit board. Licensed technician only
E517 The heater found a problem with its internal setup switch settings. Licensed technician only
E593 The control detected a problem with a front panel button. Licensed technician only
E594 The control detected a fault in the chip that stores its settings. Licensed technician only
E615 The control detected a fault with its input signals or memory. Licensed technician only
E736 The linked units are having trouble communicating with each other. Licensed technician only
E740 The heater cannot get a reliable reading from the outdoor temperature sensor. Licensed technician only
E760 The heater is signaling that routine service is due. Safe to check yourself
E762 The heater detected that the exhaust pipe is not fully seated. Licensed technician only
E773 The heater detected the wrong fuel type. Licensed technician only
E782 The display panel and main control are having trouble communicating. Licensed technician only
E785 The flow switch or flow sensor reported a problem. Licensed technician only
E788 The control detected that the panel fuel setting and the selected fuel type disagree. Licensed technician only
E

NPN non-condensing tankless

Dark narrow front panel with a rectangular number display at the top.

Below it are diagnostics, information and reset controls on the left, and plus, minus and power on the right. The indoor NPN-U has the Navien name below the buttons. On the outdoor NPN-E use an installed remote, if present, and read NPN from the rating plate.30 Used on: NPN-U indoor and NPN-E outdoor non-condensing tankless models listed in the user's manual.

E003 The burner did not light. Licensed technician only
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E046 The heater detected a fault with its temperature safety circuit. Licensed technician only
E056 The gas valve that adjusts burner output is reporting a fault. Licensed technician only
E109 The heater detected a problem with the combustion fan. Licensed technician only
E110 The heater detected a problem with airflow through the air intake or exhaust. Licensed technician only
E127 The heater detected a fault in the airflow measuring circuit. Licensed technician only
E157 The heater detected a problem controlling how much air goes to the burner. Licensed technician only
E170 The freeze-protection heater circuit is open or shorted. Licensed technician only
E407 The primary hot water outlet temperature sensor circuit has a fault. Licensed technician only
E421 The primary cold water inlet temperature sensor circuit has a fault. Licensed technician only
E434 The valve that adjusts water flow is reporting a fault. Licensed technician only
E438 The heater reported a problem with the circulation pump. Licensed technician only
E439 The heater reported a problem with its water flow sensor. Licensed technician only
E441 The second hot-water inlet temperature sensor circuit is open or shorted. Licensed technician only
E445 The internal bypass mixing valve reported a fault. Licensed technician only
E515 The heater detected a problem with its main circuit board. Licensed technician only
E517 The heater found a problem with its internal setup switch settings. Licensed technician only
E593 The control detected a problem with a front panel button. Licensed technician only
E594 The control detected a fault in the chip that stores its settings. Licensed technician only
E615 The control detected a fault with its input signals or memory. Licensed technician only
E736 The linked units are having trouble communicating with each other. Licensed technician only
E740 The heater cannot get a reliable reading from the outdoor temperature sensor. Licensed technician only
E760 The heater is signaling that routine service is due. Safe to check yourself
E762 The heater detected that the exhaust pipe is not fully seated. Licensed technician only
E773 The heater reported a problem with the gas connection. Licensed technician only
E782 The display panel and main control are having trouble communicating. Licensed technician only
E785 The flow switch or flow sensor reported a problem. Licensed technician only
E786 The heater reported a panel connection fault. Licensed technician only

Older NR / NP tankless

Look for a wired wall control with a number display above two rows of three rectangular buttons.

The top row includes Function and Lock. The bottom row includes PRO and Power. Confirm NR or NP on the appliance rating plate.33 Used on: NR-180/210/240 and NP-180/210/240, including the A variants in the operation and installation manual.

E001 The control detected water boiling inside the heat exchanger. Licensed technician only
E003 The burner did not light. Licensed technician only
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E007 The hot water outlet temperature sensor circuit is open. Licensed technician only
E008 The hot water outlet temperature sensor circuit is shorted. Licensed technician only
E009 The heater detected a problem with its fan. Licensed technician only
E010 The heater detected abnormal air pressure. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E015 The heater detected a control board fault. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E021 The cold water inlet temperature sensor circuit is open. Licensed technician only
E022 The cold water inlet temperature sensor circuit is shorted. Licensed technician only
E027 The air pressure sensor reported a problem. Licensed technician only
E030 The heater shut down because the exhaust temperature was too high. Licensed technician only
E032 The cold water inlet temperature sensor circuit is open. Licensed technician only
E033 The cold water inlet temperature sensor circuit is shorted. Licensed technician only
E034 The valve that adjusts water flow is reporting a fault. Licensed technician only
E035 The gas pressure sensor reported a problem. Licensed technician only
E036 The heater detected a communication fault. Licensed technician only
E037 The heater detected water leaking inside the unit. Shut off safely and call a plumber
E038 The heater reported a fault with the circulation pump. Licensed technician only
E039 The control detected a problem with the water flow sensor. Licensed technician only
E041 The hot water outlet temperature sensor circuit is open. Licensed technician only
E042 The hot water outlet temperature sensor circuit is shorted. Licensed technician only
E043 The linked heaters reported a connection fault. Licensed technician only
E044 The heater detected a thermostat connection fault. Licensed technician only
E045 The internal mixing valve reported a fault. Licensed technician only
E048 The heater detected abnormal propane supply pressure. Licensed technician only

Not sure which model?

Look up a code on every model
E001 Depends on the model

Legacy NR/NP and CH describe boiling. Later combis report heat exchanger overheat. Confirm the model.

E002 Water pressure in the home-heating loop is too low. Licensed technician only
E003 Depends on the model
E004 The heater detected a flame signal when the burner was meant to be off. Licensed technician only
E005 The space-heating supply temperature sensor circuit is open. Licensed technician only
E006 The space-heating supply temperature sensor circuit is shorted. Licensed technician only
E007 The hot water outlet temperature sensor circuit is open. Licensed technician only
E008 The hot water outlet temperature sensor circuit is shorted. Licensed technician only
E009 The heater detected a problem with its fan. Licensed technician only
E010 The heater detected abnormal air pressure. Licensed technician only
E011 Pressure in the home-heating loop is too high. Licensed technician only
E012 The burner lit but the heater lost the flame. Licensed technician only
E013 The boiler detected a pump problem. Licensed technician only
E015 The heater detected a control board fault. Licensed technician only
E016 The heat exchanger got too hot. Licensed technician only
E018 The space-heating return temperature sensor circuit is open. Licensed technician only
E019 The space-heating return temperature sensor circuit is shorted. Licensed technician only
E020 The boiler reports a problem with its gas control valve. Licensed technician only
E021 Depends on the model
E022 Depends on the model
E027 The air pressure sensor reported a problem. Licensed technician only
E028 The boiler detected a leak in the home-heating loop. Shut off safely and call a plumber
E030 Depends on the model

Confirm the model. NCB-E labels this an abnormal exhaust temperature, while other listed charts specify overheating.

E031 The heater detected burner overheating. Licensed technician only
E032 The cold water inlet temperature sensor circuit is open. Licensed technician only
E033 The cold water inlet temperature sensor circuit is shorted. Licensed technician only
E034 The valve that adjusts water flow is reporting a fault. Licensed technician only
E035 The gas pressure sensor reported a problem. Licensed technician only
E036 The heater detected a communication fault. Licensed technician only
E037 The heater detected water leaking inside the unit. Shut off safely and call a plumber
E038 The heater reported a fault with the circulation pump. Licensed technician only
E039 The control detected a problem with the water flow sensor. Licensed technician only
E040 The outdoor temperature sensor circuit is shorted. Licensed technician only
E041 The hot water outlet temperature sensor circuit is open. Licensed technician only
E042 The hot water outlet temperature sensor circuit is shorted. Licensed technician only
E043 The linked heaters reported a connection fault. Licensed technician only
E044 The heater detected a thermostat connection fault. Licensed technician only
E045 The internal mixing valve reported a fault. Licensed technician only
E046 Depends on the model

The later combi charts specify the heat exchanger temperature sensor. Other charts use the broader temperature limit control.

E047 The exhaust temperature sensor circuit has a fault. Licensed technician only
E048 The heater detected abnormal propane supply pressure. Licensed technician only
E056 The gas valve that adjusts burner output is reporting a fault. Licensed technician only
E060 The heater detected a fault in the part that helps mix gas and air for the burner. Licensed technician only
E109 The heater detected a problem with the combustion fan. Licensed technician only
E110 Depends on the model

The later combi charts specify exhaust blockage. Other charts report an abnormal air pressure reading.

E123 The boiler detected a blower fault. Licensed technician only
E127 The heater detected a fault in the airflow measuring circuit. Licensed technician only
E157 The heater detected a problem controlling how much air goes to the burner. Licensed technician only
E170 The freeze-protection heater circuit is open or shorted. Licensed technician only
E205 The temperature sensor on the heating supply side reported a problem. Licensed technician only
E218 The temperature sensor on the heating return side reported a problem. Licensed technician only
E278 The boiler cannot read the external heating supply temperature sensor. Licensed technician only
E279 The boiler cannot read the external heating return temperature sensor. Licensed technician only
E302 The boiler detected low water pressure in the heating loop. Licensed technician only
E351 The valve that automatically adds water to the heating loop is reporting a fault. Licensed technician only
E352 The boiler detected high water pressure in the heating loop. Licensed technician only
E353 The water pressure sensor has a fault. Licensed technician only
E407 The primary hot water outlet temperature sensor circuit has a fault. Licensed technician only
E421 The primary cold water inlet temperature sensor circuit has a fault. Licensed technician only
E432 The second cold water inlet temperature sensor circuit has a fault. Licensed technician only
E434 The valve that adjusts water flow is reporting a fault. Licensed technician only
E438 The heater reported a problem with the circulation pump. Licensed technician only
E439 Depends on the model

Later combi charts report no domestic water flow. Earlier charts identify a flow sensor fault.

E441 Depends on the model

The NPE and NPN manuals label the fault at the second hot-water inlet. The later combi manuals label their second outlet sensor.

E445 Depends on the model
E515 The heater detected a problem with its main circuit board. Licensed technician only
E517 The heater found a problem with its internal setup switch settings. Licensed technician only
E593 The control detected a problem with a front panel button. Licensed technician only
E594 The control detected a fault in the chip that stores its settings. Licensed technician only
E598 The control reported a problem communicating with its internal clock. Licensed technician only
E615 Depends on the model

Later combi charts identify a memory fault. The other charts also mention input signals.

E736 The linked units are having trouble communicating with each other. Licensed technician only
E740 Depends on the model

Later combis report an outdoor sensor they cannot detect. Other charts describe an outdoor sensor fault.

E760 The heater is signaling that routine service is due. Safe to check yourself
E761 The boiler cannot detect the temperature switch for the preheat pump. Licensed technician only
E762 Depends on the model
E773 Depends on the model

The NPN chart names a gas connection fault. Other listed families name the wrong fuel type or a fuel setup mismatch.

E777 Depends on the model

NCB-E describes abnormal low-water cutoff operation. Later combi manuals specify that it activated.

E782 The display panel and main control are having trouble communicating. Licensed technician only
E784 The boiler is having trouble communicating with the controller for its heating zones. Licensed technician only
E785 The flow switch or flow sensor reported a problem. Licensed technician only
E786 Depends on the model

NPN reports a panel connection fault. Later combis identify an incorrect front panel.

E788 Depends on the model

How old is your heater?

Sources

38 numbered notes from 26 documents
  1. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveA. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765↑
  2. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
  3. U.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
  4. Technical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, pages 2, 7. 2018-02-07U.S. Fire Administration: Home Fire Escape Plans↑
  5. A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 25. 100307779 / 2000560245 Rev. BSupports the scald hazard. The manual also describes turning off the gas supply during a large discharge. This site says to keep clear and leave instead, because the valves are next to the scalding water.A. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveSupports hazard. Evacuation and 911 escalation follow the project safety tier.Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 42. U334-0773(00)↑
  6. A. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Supports hazard and ignition precautions. Evacuation follows the project safety tier.Pacific Gas and Electric Company: Gas Safety↑
  7. Navien, Inc.: CH-ASME combi boiler operation manual, pages 13, 40, 42. CH operation PDF, legacy English edition (PDF created 2010)↑
  8. Navien, Inc.: CH-ASME combi boiler operation manual, page 42. CH operation PDF, legacy English edition (PDF created 2010)↑
  9. Navien, Inc.: CH-ASME combi boiler operation manual, page 43. CH operation PDF, legacy English edition (PDF created 2010)↑
  10. Navien, Inc.: NCB-E condensing combi-boilers user's information manual, pages 1, 7. 20035566B, v6.0, May 2019↑
  11. Navien, Inc.: NCB-E condensing combi-boilers user's information manual, page 22. 20035566B, v6.0, May 2019↑
  12. Navien, Inc.: NCB-H condensing combi-boilers installation and operation manual, pages 1, 110. v1.0, February 2024Navien, Inc.: NCB-H condensing combi-boilers user's information manual, page 8. 20050970B, v1.0, January 2025↑
  13. Navien, Inc.: NCB-H condensing combi-boilers installation and operation manual, page 129. v1.0, February 2024↑
  14. Navien, Inc.: NCB-H condensing combi-boilers user's information manual, page 25. 20050970B, v1.0, January 2025↑
  15. Navien, Inc.: NCB-H condensing combi-boilers installation and operation manual, page 130. v1.0, February 2024↑
  16. Navien, Inc.: NCB700 condensing combi-boilers installation and operation manual, pages 1, 114. v1.0, July 2026↑
  17. Navien, Inc.: NCB700 condensing combi-boilers installation and operation manual, page 136. v1.0, July 2026↑
  18. Navien, Inc.: NCB700 condensing combi-boilers installation and operation manual, page 137. v1.0, July 2026↑
  19. Navien, Inc.: NFC-H condensing combi-boilers user's information manual, pages 1, 8. 20052125A, v1.0, April 2024Navien, Inc.: NFC-H condensing combi-boilers installation manual, page 127. v1.0, March 2021↑
  20. Navien, Inc.: NFC-H condensing combi-boilers user's information manual, page 24. 20052125A, v1.0, April 2024↑
  21. Navien, Inc.: NFC-H condensing combi-boilers user's information manual, page 25. 20052125A, v1.0, April 2024↑
  22. Navien, Inc.: NHW700 non-condensing water heaters installation manual, pages 1, 8. v1.1, February 2024Navien, Inc.: NHW700 non-condensing water heaters user's information manual, page 23. v1.1, November 2023↑
  23. Navien, Inc.: NHW700 non-condensing water heaters installation manual, page 46. v1.1, February 2024↑
  24. Navien, Inc.: NHW700 non-condensing water heaters installation manual, page 23. v1.1, February 2024↑
  25. Navien, Inc.: NPE condensing water heaters operation manual, pages 1, 7. v5.1, February 2016↑
  26. Navien, Inc.: NPE condensing water heaters operation manual, page 16. v5.1, February 2016↑
  27. Navien, Inc.: NPE-2 condensing water heaters user's information manual, pages 1, 8. 20049624A, v1.0, 2020↑
  28. Navien, Inc.: NPE-2 condensing water heaters user's information manual, page 17. 20049624A, v1.0, 2020↑
  29. Navien, Inc.: NPE-2 condensing water heaters user's information manual, page 18. 20049624A, v1.0, 2020↑
  30. Navien, Inc.: NPN non-condensing water heaters user's information manual, pages 1, 8, 21. 20045995B, v1.0, December 2020Navien, Inc.: NPN non-condensing water heaters installation and operation manual, page 8. v1.0, June 2021↑
  31. Navien, Inc.: NPN non-condensing water heaters user's information manual, page 22. 20045995B, v1.0, December 2020↑
  32. Navien, Inc.: NPN non-condensing water heaters user's information manual, page 23. 20045995B, v1.0, December 2020↑
  33. Navien, Inc.: NR/NP condensing water heater total operation and installation manual, pages 1, 72, 103. NR/NP 2010-10-12 (PDF title)↑
  34. Navien, Inc.: NR/NP condensing water heater total operation and installation manual, page 102. NR/NP 2010-10-12 (PDF title)↑
  35. Navien, Inc.: NR/NP condensing water heater total operation and installation manual, page 103. NR/NP 2010-10-12 (PDF title)↑
  36. A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 24. 100307779 / 2000560245 Rev. BA. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 14. 325321-000Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 53. U334-0773(00)Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape Plans
  37. A. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveCenters for Disease Control and Prevention: Safety Guidelines: Reentering Your Flooded HomeA. O. Smith: Residential Electric Water Heaters, Models 6–120, page 19. 185762-002Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 65. U334-0773(00)
  38. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveTechnical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, page 2. 2018-02-07Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 54. U334-0773(00)

Facts checked November 27, 2026, against documents retrieved November 27, 2026. Independent site, not affiliated with Navien. Your heater’s manual and label are the final word. In an emergency, get everyone outside first and call 911 from a safe spot outside. How we check facts