Likely causes: The control is off; The pilot is out
Safe to check:
- Read the knob position without moving it. Record it only if it’s safe to do so.
Next step: Call a licensed technician if you have no hot water and this pattern continues.8
Pick the color, then count the flashes.
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
Get everyone to fresh air outside right away and call 911. Stay outside until emergency responders say it is safe to go back in.3
If you see flames coming out of the heater, smoke, or signs it may still be burning, get everyone out and call 911 from outside. Leave the heater and switches alone. If you find unexplained burn marks or melted parts and can’t tell whether there’s an active fire, get outside and call 911. If you know the damage is old and there are no other emergency signs, keep the heater out of use and call a licensed technician.4
The relief pipe is the pipe from the heater’s pressure safety valve. Keep clear of the heater, pipe and valves, even if you can’t tell where hot spray is coming from. Leave by a safe route and call 911 from outside. A slow drip without steam or other warning signs calls for safe shutoff and a plumber.5
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
What does the light look like?
How does it flash?
Count the flashes between two pauses.
Which of the six lights are on?
Count from the left. Tap each light that is on.
After a short pause, is there a second group of flashes?
Which control does your heater have?
Some look alike, so match the model on the label too. If you can’t read the label safely, choose “I’m not sure.”
What is the separate light on the gas valve doing?
The gas valve has its own light, below the box you counted. Look at it from where you are standing.
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
We can’t confirm this code for your heater. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside now. Call 911 from a safe place outside. Leave the heater and switches alone. If you see steam near the heater or water gushing or spraying from the relief pipe, get outside and call 911 from outside. Do the same if you find unexplained burn marks or melted parts and can’t tell if there is an active fire. If there are no warning signs, contact the manufacturer or a licensed technician with your model number and the full code or flash pattern.60
We can’t confirm what this means without the timing and the second light. Call a licensed water heater technician with the model and what you saw.
Gray, almost square valve at the bottom front. The large dial on the left is red in the service photo, with a smaller red igniter below it and a small green-only status lamp high on the right. Look for a direct-vent connection and confirm RG2DV or LG2DV on the rating plate.7 Used on: Direct-vent RG2DV40S, RG2DV50S, RG2DV50H and LG2DV50H50 listed in manual 238-51636-00D.
Likely causes: The control is off; The pilot is out
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.8
Green light: Steady light.
Safe to check:
Next step: Call if the heater has no hot water and the light stays on well after shutdown.8
Green light: 1 flash every 3 seconds.
Next step: No service is needed for this normal pattern.8
Green light: 1 flash every second.
Next step: No service is needed for this normal pattern.8
Green light: 2 flashes, then a 3-second pause.
Likely causes: A weak pilot flame; A bad pilot power cell (thermopile); A restricted pilot tube
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8
Green light: 3 flashes, then a 3-second pause.
Likely causes: A faulty temperature reading; A gas control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8
Green light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9
Green light: 5 flashes, then a 3-second pause.
Likely causes: A damaged sensor or wire; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Green light: 7 flashes, then a 3-second pause.
Likely causes: Moisture or damage to the gas control; An internal control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
Green light: 8 flashes, then a 3-second pause.
Likely cause: A pilot valve stuck open
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9
Look for Honeywell below the lens and confirm an early U-series model. The lamp can flash red during normal pilot operation.11 Used on: Early ultra-low-NOx U-series models listed in manual 47132 A.
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.12
Red light: Steady light.
Safe to check:
Next step: Call if the heater has no hot water and the light stays on well after shutdown.12
Red light: 1 flash every 3 seconds.
Next step: No service is needed for this normal pattern.12
Red light: 2 flashes, then a 3-second pause.
Likely causes: A weak pilot flame; A bad pilot power cell (thermopile); A restricted pilot tube
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.12
Red light: 3 flashes, then a 3-second pause.
Likely causes: A faulty temperature reading; A gas control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.12
Red light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13
Red light: 5 flashes, then a 3-second pause.
Likely causes: A damaged sensor or wire; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13
Red light: 6 flashes, then a 3-second pause.
Likely causes: A sensor fault; An electrical short
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Red light: 7 flashes, then a 3-second pause.
Likely causes: Moisture or damage to the gas control; An internal control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
Red light: 8 flashes, then a 3-second pause.
Likely cause: A pilot valve stuck open
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13
Red light: 10 flashes, then a 3-second pause.
Likely cause: Restricted combustion air
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13
Gray, almost square valve at the bottom front. The large dial on the left is red in the service photo, with a smaller red igniter below it and a small green-only status lamp high on the right. It can look like the standard ICON V1. Confirm ECO Defender and the URG model on the tank label.14 Used on: Natural-gas URG-series ECO Defender heaters with V1 control.
Likely causes: The control is off; The pilot is out
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.15
Green light: Steady light.
Safe to check:
Next step: Call if the heater has no hot water and the light stays on well after shutdown.15
Green light: 1 flash every 3 seconds.
Next step: No service is needed for this normal pattern.15
Green light: 2 flashes, then a 3-second pause.
Likely causes: A weak pilot flame; A bad pilot power cell (thermopile); A restricted pilot tube
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15
Green light: Two quick flashes, then a 3-second pause.
Next step: No service is needed for this normal pattern.15
Green light: 3 flashes, then a 3-second pause.
Likely causes: A faulty temperature reading; A gas control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15
Green light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16
Green light: 5 flashes, then a 3-second pause.
Likely causes: A damaged sensor or wire; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16
Green light: 6 flashes, then a 3-second pause.
Likely causes: A sensor fault; An electrical short
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Green light: 7 flashes, then a 3-second pause.
Likely causes: Moisture or damage to the gas control; An internal control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
Green light: 8 flashes, then a 3-second pause.
Likely cause: A pilot valve stuck open
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16
Green light: 10 flashes, then a 3-second pause.
Likely cause: Restricted combustion air
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16
Gray, roughly square face at the bottom front, with a large black dial on the left and a small square STATUS window at upper right. The face may say ICON System. The same window can show green, yellow or red. Match the model if it is only blinking green. Confirm ECO Defender and the URG model on the tank label.17 Used on: Natural-gas URG-series ECO Defender heaters with V2 control.
Likely causes: The control is off; The pilot is out
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.18
Red light: Steady light.
Safe to check:
Next step: Call if the heater has no hot water and the light stays on well after shutdown.19
Green light: 1 flash, about every 4 seconds.
Next step: No service is needed for this normal pattern.18
Green light: 1 flash every second.
Next step: No service is needed for this normal pattern.18
Amber light: 2 flashes, then a 3-second pause.
Likely causes: A weak pilot flame; A loose connection to the pilot power cell (thermopile)
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.18
Red light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.18
Red light: 5 flashes, then a 3-second pause.
Likely causes: A faulty temperature sensor or connection; A gas control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.19
Red light: 6 flashes, then a 3-second pause.
Likely cause: A faulty sensor or connection
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.19
Red light: 9 flashes, then a 3-second pause.
Likely cause: A leak leaving water around the heater
If you see steam or water spraying from the relief pipe, get outside and call 911 from outside. Stay back if water is near the heater’s wiring, plug or breaker panel. Look for water only from a dry spot after the cold water and every power or gas shutoff required by your heater’s manual are off. The front OFF button alone does not count. If you cannot shut it off safely, skip the check and call a licensed plumber.
Next step: Call a licensed plumber when this leak code appears, even if no water is visible.19
Red light: 10 flashes, then a 3-second pause.
Likely causes: Restricted combustion air; A burner problem
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.19
A large temperature dial is centered on the face, with a status light above it. Look for ICON System and VACATION. It has no PILOT setting.20 Used on: Electric tank heaters with the tricolor ICON E electronic control, including the models covered in 238-54223-00D.
Likely causes: Loss of power; A disconnected control
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.21
Green light: Steady light.
Next step: No service is needed for this normal pattern.22
Green light: 1 green flash, then 3.5 seconds dark.
Next step: No service is needed for this normal pattern.22
Amber light: 2 flashes followed by a 4-second pause.
Likely cause: A bad heating element
Safe to check:
Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22
Amber light: 3 flashes followed by a 4-second pause.
Likely causes: A failing power switch module; Poor contact between the module and the tank
Safe to check:
Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22
Amber light: 4 flashes followed by a 4-second pause.
Likely cause: A bad sensor or loose connection
Safe to check:
Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22
Amber light: 5 flashes followed by a 4-second pause.
Likely cause: A failing electronic control
Safe to check:
Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22
Amber light: 6 flashes followed by a 4-second pause.
Likely causes: A disconnected or faulty utility adapter; An active utility demand response event
Safe to check:
Next step: Use the exact model's manual. Call a licensed technician if there is no matching utility notice.22
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Red light: 7 flashes followed by a 4-second pause.
Likely cause: A high temperature reading from the upper or lower sensor
Safe to check:
Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22
Next step: No service is needed for this normal pattern.22
Gray, almost square valve at the bottom front. The large dial on the left is red in the service photo, with a smaller red igniter below it and a small green-only status lamp high on the right. Some older manuals call this control Honeywell. A Defender label alone doesn’t tell it apart from other versions.23 Used on: Standard atmospheric Defender RG and LG models and matching legacy atmospheric ICON V1 controls. The January 2019 changeover is a guide. For RG2DV or LG2DV direct-vent models, match the separate DV Series chart.
Likely causes: The control is off; The pilot is out
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.24
Green light: Steady light.
Safe to check:
Next step: Call if the heater has no hot water and the light stays on well after shutdown.24
Green light: 1 flash every 3 seconds.
Next step: No service is needed for this normal pattern.24
Green light: 2 flashes, then a 3-second pause.
Likely causes: A weak pilot flame; A bad pilot power cell (thermopile); A restricted pilot tube
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.24
Green light: Two quick flashes, then a 3-second pause.
Next step: No service is needed for this normal pattern.25
Green light: 3 flashes, then a 3-second pause.
Likely causes: A faulty temperature reading; A gas control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.24
Green light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.26
Green light: 5 flashes, then a 3-second pause.
Likely causes: A damaged sensor or wire; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27
Green light: 6 flashes, then a 3-second pause.
Likely cause: A leak leaving water in the drain pan
If you see steam or water spraying from the relief pipe, get outside and call 911 from outside. Stay back if water is near the heater’s wiring, plug or breaker panel. Look for water only from a dry spot after the cold water and every power or gas shutoff required by your heater’s manual are off. The front OFF button alone does not count. If you cannot shut it off safely, skip the check and call a licensed plumber.
Next step: Call a licensed plumber when this leak code appears, even if no water is visible.27
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Green light: 7 flashes, then a 3-second pause.
Likely causes: Moisture or damage to the gas control; An internal control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
Green light: 8 flashes, then a 3-second pause.
Likely cause: A pilot valve stuck open
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27
Gray, roughly square face at the bottom front, with a large black dial on the left and a small square STATUS window at upper right. The face may say ICON System. The same window can show green, yellow or red. Match the model if it is only blinking green.28 Used on: Standard atmospheric Defender RG and LG models with ICON V2. The broader ICON 2.0 quick guide uses Jan 2019 as its changeover reference and lists an optional leak accessory. Also DV Series with the matching valve.
Likely causes: The control is off; The pilot is out
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.29
Red light: Steady light.
Safe to check:
Next step: Call if the heater has no hot water and the light stays on well after shutdown.29
Green light: 1 flash, about every 4 seconds.
Next step: No service is needed for this normal pattern.29
Green light: 1 flash every second.
Next step: No service is needed for this normal pattern.29
Amber light: 2 flashes, then a 3-second pause.
Likely causes: A weak pilot flame; A loose connection to the pilot power cell (thermopile)
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29
Red light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29
Red light: 5 flashes, then a 3-second pause.
Likely causes: A faulty temperature sensor or connection; A gas control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29
6 flashes, then a 3-second pause.
Only on ICON 2.0 models with the leak accessory and this code in their manual.
Likely cause: A leak leaving water around the heater
If you see steam or water spraying from the relief pipe, get outside and call 911 from outside. Stay back if water is near the heater’s wiring, plug or breaker panel. Look for water only from a dry spot after the cold water and every power or gas shutoff required by your heater’s manual are off. The front OFF button alone does not count. If you cannot shut it off safely, skip the check and call a licensed plumber.
Next step: Call a licensed plumber when this leak code appears, even if no water is visible.30
Look for a powered blower at the top beside the vent and a power cord.31 Used on: ICON units in the PV, PDV and RG*F fan-assisted families covered by the quick guide. Also the RG2PDV and LG2PDV models in the PDV service manual.
Likely causes: The heater switch is off; The power supply was interrupted
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.32
Green light: Alternating bright and dim.
Next step: No service is needed for this normal pattern.32
Green light: 1 flash every second.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32
Green light: 1 flash, about every 4 seconds.
Next step: No service is needed for this normal pattern.32
Green light: 2 flashes, then a 3-second pause.
Likely causes: A faulty pressure switch; A blocked or kinked air tube
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32
Green light: 3 flashes, then a 3-second pause.
Likely causes: A vent blockage; A blower or switch fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32
Green light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32
Green light: 5 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32
Green light: 6 flashes, then 1 flash, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33
Green light: 6 flashes, then 2 flashes, then a 3-second pause.
Likely causes: A vent blockage; A blower or switch fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33
Green light: 6 flashes, then 3 flashes, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33
Green light: 6 flashes, then 4 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Green light: 7 flashes, then a 3-second pause.
Likely causes: Flammable vapors; A fault in the vapor-sensing circuit; An out-of-range sensor circuit on models using a factory resistor harness
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.33
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Green light: 8 flashes, then 1 flash, then a 3-second pause.
Likely causes: A faulty vapor sensor; A possible short in the sensing circuit; An out-of-range sensor circuit on models using a factory resistor harness
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.33
Green light: 8 flashes, then 2 flashes, then a 3-second pause.
Likely causes: A damaged sensor or wire; A loose connection
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33
Green light: 8 flashes, then 3 flashes, then a 3-second pause.
Likely causes: Moisture or damage to the gas control; An internal control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33
Green light: 8 flashes, then 4 flashes, then a 3-second pause.
Likely cause: A damaged or failing gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33
The oblong low-front gas control has the separate ON/OFF rocker near its top center and a green lamp above the temperature dial on the right.34 Used on: PE4403S, PE440T, PE4503F and PE2XR504T variants listed in the PE supplement.
Likely causes: The heater switch is off; The power supply was interrupted
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.35
Green light: Alternating bright and dim.
Next step: No service is needed for this normal pattern.35
Green light: 1 flash every second.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35
Green light: 1 flash, about every 4 seconds.
Next step: No service is needed for this normal pattern.35
Green light: 2 flashes, then a 3-second pause.
Likely cause: A faulty relay
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35
Green light: 3 flashes, then a 3-second pause.
Likely cause: A faulty relay
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35
Green light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35
Green light: 5 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35
Green light: 6 flashes, then 1 flash, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35
Green light: 6 flashes, then 2 flashes, then a 3-second pause.
Likely cause: A failing relay
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36
Green light: 6 flashes, then 3 flashes, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36
Green light: 6 flashes, then 4 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
Green light: 7 flashes, then a 3-second pause.
Likely causes: Flammable vapors; Moisture or extreme temperature affecting the vapor sensor; An open thermal safety switch
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.36
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Green light: 8 flashes, then 1 flash, then a 3-second pause.
Likely causes: A faulty vapor sensor; A possible short in the sensing circuit
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.36
Green light: 8 flashes, then 3 flashes, then a 3-second pause.
Likely causes: A damaged or unplugged temperature probe; A failing gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36
Green light: 8 flashes, then 4 flashes, then a 3-second pause.
Likely cause: A damaged or failing gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36
The small status lamp is near the upper-right corner. Look for a motor box on the metal vent at the top and match the model on the rating plate. The vent flap cover distinguishes it from a blower housing when the valve faces look alike.37 Used on: RG1D and RG2D in the installation manual. Only look up a 6-2 pattern under the damper chart if the exact model documentation includes it.
Likely causes: The heater switch is off; The power supply was interrupted
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.38
Alternating bright and dim.
Next step: No service is needed for this normal pattern.38
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38
Next step: No service is needed for this normal pattern.38
2 flashes, then a 3-second pause.
Likely causes: A stuck vent flap; A vent blockage
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38
3 flashes, then a 3-second pause.
Likely causes: A stuck vent flap; A vent blockage
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38
4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38
5 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38
6 flashes, then 1 flash, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38
6 flashes, then 2 flashes, then a 3-second pause.
Only if this pattern is listed for the exact model.
Likely causes: A vent blockage; A failing damper
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.39
6 flashes, then 3 flashes, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40
6 flashes, then 4 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
7 flashes, then a 3-second pause.
Likely causes: Flammable vapors; Moisture or extreme temperature affecting the vapor sensor; An open thermal safety switch
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.40
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
8 flashes, then 1 flash, then a 3-second pause.
Likely causes: A faulty vapor sensor; A possible short in the sensing circuit
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.40
8 flashes, then 2 flashes, then a 3-second pause.
Likely causes: A damaged sensor or wire; A loose connection
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40
8 flashes, then 3 flashes, then a 3-second pause.
Likely causes: Moisture or damage to the gas control; An internal control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40
8 flashes, then 4 flashes, then a 3-second pause.
Likely cause: A damaged or failing gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40
The face resembles electronic White-Rodgers. Confirm SIT in the exact heater manual.41 Used on: Standard Defender RG atmospheric models that list SIT as the fitted control in the July 2026 instructions.
Likely causes: The control is off; The pilot is out
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.42
Safe to check:
Next step: Call if the heater has no hot water and the light stays on well after shutdown.42
Next step: No service is needed for this normal pattern.42
Next step: No service is needed for this normal pattern.42
2 flashes, then a 3-second pause.
Likely causes: A weak pilot flame; A loose connection to the pilot power cell (thermopile)
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.42
4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.42
5 flashes, then a 3-second pause.
Likely causes: A faulty temperature sensor or connection; A gas control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.42
Look for a powered blower and power cord. The face can resemble other powered ICON controls. Match a TTW, PDX or GXTW model to its manual.43 Used on: TTW, PDX and GXTW lines in the older quick guide. Use the exact TTW model manual for 8-2 or 8-3.
Likely causes: The heater switch is off; The power supply was interrupted
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.44
Alternating bright and dim.
Next step: No service is needed for this normal pattern.44
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44
Next step: No service is needed for this normal pattern.44
2 flashes, then a 3-second pause.
Likely causes: A faulty pressure switch; A blocked or kinked air tube
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44
3 flashes, then a 3-second pause.
Likely causes: A vent blockage; A blower or switch fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44
4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44
5 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44
6 flashes, then 1 flash, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45
6 flashes, then 2 flashes, then a 3-second pause.
Likely causes: A vent blockage; A blower or switch fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45
6 flashes, then 3 flashes, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45
6 flashes, then 4 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
7 flashes, then a 3-second pause.
Likely causes: Flammable vapors; A fault in the vapor-sensing circuit; An out-of-range factory resistor harness on certain TTW models
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.46
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
8 flashes, then 1 flash, then a 3-second pause.
Likely causes: A faulty vapor sensor; A possible short in the sensing circuit; An out-of-range factory resistor harness on certain TTW models
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.46
Green light: 8 flashes, then 2 flashes, then a 3-second pause.
TTW models using the 238-46238A-00B service chart.
Likely cause: A damaged or loose temperature probe
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.47
8 flashes, then 3 flashes, then a 3-second pause.
Check the exact manual. The TTW service manual limits 8-3 to electronics. The TTW/PDX/GXTW quick guide also lists the temperature probe.
Likely causes: A damaged or unplugged temperature probe; A failing gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.46
8 flashes, then 4 flashes, then a 3-second pause.
Likely cause: A damaged or failing gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45
The small status lamp is near the upper-right corner. Look for a motor box on the metal vent at the top and match the model on the rating plate. Confirm the URG1D or URG2D model on the label.48 Used on: Natural-gas URG1D and URG2D Ultra Low NOx models in the service manual.
Likely causes: The heater switch is off; The power supply was interrupted
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.49
Green light: Alternating bright and dim.
Next step: No service is needed for this normal pattern.49
Green light: 1 flash every second.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49
Green light: 1 flash about every 2 seconds on the cited D Series chart.
Next step: No service is needed for this normal pattern.50
Green light: 2 flashes, then a 3-second pause.
Likely causes: A stuck vent flap; A vent blockage
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49
Green light: 3 flashes, then a 3-second pause.
Likely causes: A stuck vent flap; A vent blockage
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49
Green light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49
Green light: 5 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49
Green light: 6 flashes, then 1 flash, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51
Green light: 6 flashes, then 2 flashes, then a 3-second pause.
Likely causes: A faulty vent flap; A vent blockage
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51
Green light: 6 flashes, then 3 flashes, then a 3-second pause.
Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51
Green light: 6 flashes, then 4 flashes, then a 3-second pause.
Likely causes: A pilot valve stuck open; A flame-sensor wiring fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
Green light: 7 flashes, then a 3-second pause.
Likely causes: Flammable vapors; Moisture or extreme temperature affecting the vapor sensor; An open thermal safety switch
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.51
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Green light: 8 flashes, then 1 flash, then a 3-second pause.
Likely causes: A faulty vapor sensor; A possible short in the sensing circuit
Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.51
Green light: 8 flashes, then 2 flashes, then a 3-second pause.
Likely causes: A damaged sensor or wire; A loose connection
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51
Green light: 8 flashes, then 3 flashes, then a 3-second pause.
Likely causes: Moisture or damage to the gas control; An internal control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51
Green light: 8 flashes, then 4 flashes, then a 3-second pause.
Likely cause: A damaged or failing gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51
Green light: 9 flashes, then 1 flash, then a 3-second pause.
Likely cause: Restricted combustion air
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.52
Green light: 9 flashes, then 2 flashes, then a 3-second pause.
Likely causes: A faulty sensor; An electrical short
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.52
The green status lens is low near the middle, below the printed instructions. The separate dark igniter is at the lower right.53 Used on: Selected standard Defender RG and LG atmospheric models with the White-Rodgers electronic valve shown in the 2022 manual. Also DV Series with the matching valve.
Likely causes: The control is off; The pilot is out
Safe to check:
Next step: Call a licensed technician if you have no hot water and this pattern continues.54
Green light: Steady light.
Safe to check:
Next step: Call if the heater has no hot water and the light stays on well after shutdown.54
Green light: 1 flash, about every 4 seconds.
Next step: No service is needed for this normal pattern.54
Green light: 1 flash every second.
Next step: No service is needed for this normal pattern.54
Green light: 2 flashes, then a 3-second pause.
Likely causes: A weak pilot flame; A loose connection to the pilot power cell (thermopile)
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.54
Green light: 4 flashes, then a 3-second pause.
Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.54
Green light: 5 flashes, then a 3-second pause.
Likely causes: A faulty temperature sensor or connection; A gas control fault
Safe to check:
Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.54
A dark lamp has different meanings on standing-pilot and plug-in or electric controls. Identify the heater before interpreting a dark lamp.
Steady green means shutdown on some gas valves and normal standby on ICON E. Confirm gas versus electric.
A fast blink can mean normal heating on a standing-pilot valve or a weak pilot signal on powered models. Note how fast it blinks.
Two quick flashes can be normal on V1. The fault pattern can mean weak pilot power, an air-pressure switch, a damper fault or a relay fault.
The normal strobe uses two quick flashes close together. If you can’t tell it from the 2-flash pilot fault, check the manual for your exact heater or call a licensed technician.
Underheating on V1, a pressure or temperature switch on power vent, a damper on D Series, or a relay on the Programmable Efficiency model.
Four flashes can indicate a gas heater high-temperature cutoff, or an ICON E temperature sensor fault. Match the heater type and light color.
Tank sensor or control fault on standing-pilot units, or a pilot flame at the wrong time on powered units.
Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.
Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.
Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.
Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.
Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
Standing-pilot V1 indicates gas-control electronics. Powered gas models point to the flammable-vapor sensing circuit or a thermal switch. Red seven on an ICON E electric tank indicates high temperature. Confirm the power source, vent hardware and model label first.
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10
A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6
A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.
Before you continue
If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1
The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10
A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.
A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.
A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.
A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.
Nine red flashes on ECO V2 indicate water at the leak sensor. On the Ultra Low NOx D Series, nine is the first group of a two-part burner air or chamber sensor code.
Nine red flashes on ECO V2 indicate water at the leak sensor. On the Ultra Low NOx D Series, nine is the first group of a two-part burner air or chamber sensor code.
Nine red flashes on ECO V2 indicate water at the leak sensor. On the Ultra Low NOx D Series, nine is the first group of a two-part burner air or chamber sensor code.
Check whether you have ECO Defender V1 or V2. On V1 this means too little air reaches the burner. On V2 it means an abnormal pattern of temperatures in the burner chamber.
No status light: Mechanical Robertshaw, Mechanical White-Rodgers. This mechanical valve has no status light. Use the model's printed guide for a pilot or heating problem.
Facts checked November 27, 2026, against documents retrieved November 27, 2026. Independent site, not affiliated with Bradford White. Your heater’s manual and label are the final word. In an emergency, get everyone outside first and call 911 from a safe spot outside. How we check facts