Water Heater Decoder

Bradford White flashing light codes

Pick the color, then count the flashes.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2
Carbon monoxide alarm? Get outside

Get everyone to fresh air outside right away and call 911. Stay outside until emergency responders say it is safe to go back in.3

Flames coming out of the heater, smoke, or burn marks or melted parts that might be new? Get outside

If you see flames coming out of the heater, smoke, or signs it may still be burning, get everyone out and call 911 from outside. Leave the heater and switches alone. If you find unexplained burn marks or melted parts and can’t tell whether there’s an active fire, get outside and call 911. If you know the damage is old and there are no other emergency signs, keep the heater out of use and call a licensed technician.4

Water gushing or spraying from the safety valve’s pipe, or hot spray or steam near the heater? Leave now

The relief pipe is the pipe from the heater’s pressure safety valve. Keep clear of the heater, pipe and valves, even if you can’t tell where hot spray is coming from. Leave by a safe route and call 911 from outside. A slow drip without steam or other warning signs calls for safe shutoff and a plumber.5

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Every code, by control

Direct Vent DV Series, ICON V1

Model starts with RG2DV or LG2DV.

Gray, almost square valve at the bottom front. The large dial on the left is red in the service photo, with a smaller red igniter below it and a small green-only status lamp high on the right. Look for a direct-vent connection and confirm RG2DV or LG2DV on the rating plate.7 Used on: Direct-vent RG2DV40S, RG2DV50S, RG2DV50H and LG2DV50H50 listed in manual 238-51636-00D.

No light The valve has no power from the pilot. The pilot may be out. Safe to check yourself

Likely causes: The control is off; The pilot is out

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.8

Steady light The valve is shutting down after the knob was moved to OFF. Safe to check yourself

Green light: Steady light.

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call if the heater has no hot water and the light stays on well after shutdown.8

1 flash every 3 seconds The pilot is on. The heater is in pilot mode or the tank is up to temperature. Safe to check yourself

Green light: 1 flash every 3 seconds.

Next step: No service is needed for this normal pattern.8

1 flash every second The main burner is being called on to heat the tank. Safe to check yourself

Green light: 1 flash every second.

Next step: No service is needed for this normal pattern.8

2 flashes The control is getting a weak signal from the pilot. Licensed technician only

Green light: 2 flashes, then a 3-second pause.

Likely causes: A weak pilot flame; A bad pilot power cell (thermopile); A restricted pilot tube

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

3 flashes The tank did not warm as expected. Licensed technician only

Green light: 3 flashes, then a 3-second pause.

Likely causes: A faulty temperature reading; A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

4 flashes The gas control stopped heating because the tank temperature was too high. Licensed technician only

Green light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

5 flashes The tank temperature sensor has a fault. Licensed technician only

Green light: 5 flashes, then a 3-second pause.

Likely causes: A damaged sensor or wire; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

7 flashes The gas control detected a fault in its electronics. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 7 flashes, then a 3-second pause.

Likely causes: Moisture or damage to the gas control; An internal control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

8 flashes The control detected a pilot flame when the knob was off. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 8 flashes, then a 3-second pause.

Likely cause: A pilot valve stuck open

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

Early ECO-DEFENDER (red light)

Rectangular gas valve with a round dial on the left and a small round status lens high on the right.

Look for Honeywell below the lens and confirm an early U-series model. The lamp can flash red during normal pilot operation.11 Used on: Early ultra-low-NOx U-series models listed in manual 47132 A.

No light The status light is dark. The gas valve can be operating normally, or the pilot may be out and the valve unpowered. Safe to check yourself

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.12

Steady light The valve is shutting down after the knob was moved to OFF. Safe to check yourself

Red light: Steady light.

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call if the heater has no hot water and the light stays on well after shutdown.12

1 flash With the knob at PILOT, this pattern confirms that the pilot is lit. Safe to check yourself

Red light: 1 flash every 3 seconds.

Next step: No service is needed for this normal pattern.12

2 flashes The control is getting a weak signal from the pilot. Licensed technician only

Red light: 2 flashes, then a 3-second pause.

Likely causes: A weak pilot flame; A bad pilot power cell (thermopile); A restricted pilot tube

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.12

3 flashes The tank did not warm as expected. Licensed technician only

Red light: 3 flashes, then a 3-second pause.

Likely causes: A faulty temperature reading; A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.12

4 flashes The gas control stopped heating because the tank temperature was too high. Licensed technician only

Red light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13

5 flashes The tank temperature sensor has a fault. Licensed technician only

Red light: 5 flashes, then a 3-second pause.

Likely causes: A damaged sensor or wire; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13

6 flashes The burner door temperature sensor is giving a reading outside its normal range. Licensed technician only

Red light: 6 flashes, then a 3-second pause.

Likely causes: A sensor fault; An electrical short

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13

7 flashes The gas control detected a fault in its electronics. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Red light: 7 flashes, then a 3-second pause.

Likely causes: Moisture or damage to the gas control; An internal control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13

8 flashes The control detected a pilot flame when the knob was off. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Red light: 8 flashes, then a 3-second pause.

Likely cause: A pilot valve stuck open

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13

10 flashes The burner is getting too little air. Licensed technician only

Red light: 10 flashes, then a 3-second pause.

Likely cause: Restricted combustion air

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13

ECO Defender V1

Label says ECO Defender and the model starts with URG.

Gray, almost square valve at the bottom front. The large dial on the left is red in the service photo, with a smaller red igniter below it and a small green-only status lamp high on the right. It can look like the standard ICON V1. Confirm ECO Defender and the URG model on the tank label.14 Used on: Natural-gas URG-series ECO Defender heaters with V1 control.

No light The valve has no power from the pilot. The pilot may be out. Safe to check yourself

Likely causes: The control is off; The pilot is out

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.15

Steady light The valve is shutting down after the knob was moved to OFF. Safe to check yourself

Green light: Steady light.

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call if the heater has no hot water and the light stays on well after shutdown.15

1 flash The pilot is on. The heater is in pilot mode or the tank is up to temperature. Safe to check yourself

Green light: 1 flash every 3 seconds.

Next step: No service is needed for this normal pattern.15

2 flashes, then a 3-second pause The control is getting a weak signal from the pilot. Licensed technician only

Green light: 2 flashes, then a 3-second pause.

Likely causes: A weak pilot flame; A bad pilot power cell (thermopile); A restricted pilot tube

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

Two quick flashes, then a 3-second pause The burner is being called on to heat the tank. Safe to check yourself

Green light: Two quick flashes, then a 3-second pause.

Next step: No service is needed for this normal pattern.15

3 flashes The tank did not warm as expected. Licensed technician only

Green light: 3 flashes, then a 3-second pause.

Likely causes: A faulty temperature reading; A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

4 flashes The gas control stopped heating because the tank temperature was too high. Licensed technician only

Green light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16

5 flashes The tank temperature sensor has a fault. Licensed technician only

Green light: 5 flashes, then a 3-second pause.

Likely causes: A damaged sensor or wire; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16

6 flashes The burner door temperature sensor is giving a reading outside its normal range. Licensed technician only

Green light: 6 flashes, then a 3-second pause.

Likely causes: A sensor fault; An electrical short

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16

7 flashes The gas control detected a fault in its electronics. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 7 flashes, then a 3-second pause.

Likely causes: Moisture or damage to the gas control; An internal control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16

8 flashes The control detected a pilot flame when the knob was off. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 8 flashes, then a 3-second pause.

Likely cause: A pilot valve stuck open

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16

10 flashes The burner is getting too little air. Licensed technician only

Green light: 10 flashes, then a 3-second pause.

Likely cause: Restricted combustion air

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.16

ECO Defender V2

Label says ECO Defender and the model starts with URG.

Gray, roughly square face at the bottom front, with a large black dial on the left and a small square STATUS window at upper right. The face may say ICON System. The same window can show green, yellow or red. Match the model if it is only blinking green. Confirm ECO Defender and the URG model on the tank label.17 Used on: Natural-gas URG-series ECO Defender heaters with V2 control.

No light The gas control has no power from the pilot. Safe to check yourself

Likely causes: The control is off; The pilot is out

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.18

Steady light The gas control is in shutdown after the knob was moved to OFF. Safe to check yourself

Red light: Steady light.

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call if the heater has no hot water and the light stays on well after shutdown.19

1 flash, about every 4 seconds The pilot is on and the main burner is idle. Safe to check yourself

Green light: 1 flash, about every 4 seconds.

Next step: No service is needed for this normal pattern.18

1 flash every second The main burner is heating the water. Safe to check yourself

Green light: 1 flash every second.

Next step: No service is needed for this normal pattern.18

2 flashes The pilot is supplying too little power for the main burner to start. Licensed technician only

Amber light: 2 flashes, then a 3-second pause.

Likely causes: A weak pilot flame; A loose connection to the pilot power cell (thermopile)

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.18

4 flashes The heater shut down when the tank reached its high temperature limit. Licensed technician only

Red light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.18

5 flashes The control detected a problem with its electronics, temperature sensor or gas valve. Licensed technician only

Red light: 5 flashes, then a 3-second pause.

Likely causes: A faulty temperature sensor or connection; A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.19

6 flashes The burner door temperature sensor has failed. Licensed technician only

Red light: 6 flashes, then a 3-second pause.

Likely cause: A faulty sensor or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.19

9 flashes An add-on sensor detected water around the heater. Shut off safely and call a plumber

Red light: 9 flashes, then a 3-second pause.

Likely cause: A leak leaving water around the heater

If you see steam or water spraying from the relief pipe, get outside and call 911 from outside. Stay back if water is near the heater’s wiring, plug or breaker panel. Look for water only from a dry spot after the cold water and every power or gas shutoff required by your heater’s manual are off. The front OFF button alone does not count. If you cannot shut it off safely, skip the check and call a licensed plumber.

Shutoff steps for each type of heater

Next step: Call a licensed plumber when this leak code appears, even if no water is visible.19

10 flashes The burner chamber temperature was abnormal during heating. Licensed technician only

Red light: 10 flashes, then a 3-second pause.

Likely causes: Restricted combustion air; A burner problem

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.19

ICON E electric tank control

Dark gray and blue vertical rectangle on the front of an electric tank.

A large temperature dial is centered on the face, with a status light above it. Look for ICON System and VACATION. It has no PILOT setting.20 Used on: Electric tank heaters with the tricolor ICON E electronic control, including the models covered in 238-54223-00D.

No light The electric control has no power. Safe to check yourself

Likely causes: Loss of power; A disconnected control

Safe to check:

  • If the area is dry and safe, look to see whether the breaker has tripped.

Next step: Call a licensed technician if you have no hot water and this pattern continues.21

Steady light The tank is up to temperature and the heater is waiting. Safe to check yourself

Green light: Steady light.

Next step: No service is needed for this normal pattern.22

1 flash An electric heating element is heating the water. Safe to check yourself

Green light: 1 green flash, then 3.5 seconds dark.

Next step: No service is needed for this normal pattern.22

2 flashes The control detected a faulty electric heating element. Licensed technician only

Amber light: 2 flashes followed by a 4-second pause.

Likely cause: A bad heating element

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

3 flashes The control detected a fault in its power switch module. Licensed technician only

Amber light: 3 flashes followed by a 4-second pause.

Likely causes: A failing power switch module; Poor contact between the module and the tank

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

4 flashes The electric control detected a temperature sensor fault. Licensed technician only

Amber light: 4 flashes followed by a 4-second pause.

Likely cause: A bad sensor or loose connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

5 flashes The electric heater detected a controller fault. Licensed technician only

Amber light: 5 flashes followed by a 4-second pause.

Likely cause: A failing electronic control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

6 flashes The control reports a problem with its optional utility connection, or a utility event on some versions. Safe to check yourself

Amber light: 6 flashes followed by a 4-second pause.

Likely causes: A disconnected or faulty utility adapter; An active utility demand response event

Safe to check:

  • Look for a notice from your electric utility if you are enrolled in a service program.

Next step: Use the exact model's manual. Call a licensed technician if there is no matching utility notice.22

7 flashes The electric heater detected too much heat in the tank. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Red light: 7 flashes followed by a 4-second pause.

Likely cause: A high temperature reading from the upper or lower sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed water heater technician. Leave the covers in place and leave any reset to the technician. If you see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

Alternating amber and green The electric control has just powered on or is running its first-fill safety check. Safe to check yourself

Next step: No service is needed for this normal pattern.22

ICON V1 standing pilot

Model starts with RG or LG. If it starts with RG2DV or LG2DV, use the separate Direct Vent option.

Gray, almost square valve at the bottom front. The large dial on the left is red in the service photo, with a smaller red igniter below it and a small green-only status lamp high on the right. Some older manuals call this control Honeywell. A Defender label alone doesn’t tell it apart from other versions.23 Used on: Standard atmospheric Defender RG and LG models and matching legacy atmospheric ICON V1 controls. The January 2019 changeover is a guide. For RG2DV or LG2DV direct-vent models, match the separate DV Series chart.

No light The valve has no power from the pilot. The pilot may be out. Safe to check yourself

Likely causes: The control is off; The pilot is out

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.24

Steady light The valve is shutting down after the knob was moved to OFF. Safe to check yourself

Green light: Steady light.

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call if the heater has no hot water and the light stays on well after shutdown.24

1 flash The pilot is on. The heater is in pilot mode or the tank is up to temperature. Safe to check yourself

Green light: 1 flash every 3 seconds.

Next step: No service is needed for this normal pattern.24

2 flashes, then a 3-second pause The control is getting a weak signal from the pilot. Licensed technician only

Green light: 2 flashes, then a 3-second pause.

Likely causes: A weak pilot flame; A bad pilot power cell (thermopile); A restricted pilot tube

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.24

Two quick flashes, then a 3-second pause The thermostat is asking for heat. Safe to check yourself

Green light: Two quick flashes, then a 3-second pause.

Next step: No service is needed for this normal pattern.25

3 flashes The tank did not warm as expected. Licensed technician only

Green light: 3 flashes, then a 3-second pause.

Likely causes: A faulty temperature reading; A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.24

4 flashes The gas control stopped heating because the tank temperature was too high. Licensed technician only

Green light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.26

5 flashes The tank temperature sensor has a fault. Licensed technician only

Green light: 5 flashes, then a 3-second pause.

Likely causes: A damaged sensor or wire; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

6 flashes An add-on sensor detected water around the heater. Shut off safely and call a plumber

Green light: 6 flashes, then a 3-second pause.

Likely cause: A leak leaving water in the drain pan

If you see steam or water spraying from the relief pipe, get outside and call 911 from outside. Stay back if water is near the heater’s wiring, plug or breaker panel. Look for water only from a dry spot after the cold water and every power or gas shutoff required by your heater’s manual are off. The front OFF button alone does not count. If you cannot shut it off safely, skip the check and call a licensed plumber.

Shutoff steps for each type of heater

Next step: Call a licensed plumber when this leak code appears, even if no water is visible.27

7 flashes The gas control detected a fault in its electronics. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 7 flashes, then a 3-second pause.

Likely causes: Moisture or damage to the gas control; An internal control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

8 flashes The control detected a pilot flame when the knob was off. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 8 flashes, then a 3-second pause.

Likely cause: A pilot valve stuck open

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

ICON V2 standing pilot (Resideo)

Model starts with RG, LG, RG2DV, or LG2DV.

Gray, roughly square face at the bottom front, with a large black dial on the left and a small square STATUS window at upper right. The face may say ICON System. The same window can show green, yellow or red. Match the model if it is only blinking green.28 Used on: Standard atmospheric Defender RG and LG models with ICON V2. The broader ICON 2.0 quick guide uses Jan 2019 as its changeover reference and lists an optional leak accessory. Also DV Series with the matching valve.

No light The gas control has no power from the pilot. Safe to check yourself

Likely causes: The control is off; The pilot is out

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.29

Steady light The gas control is in shutdown after the knob was moved to OFF. Safe to check yourself

Red light: Steady light.

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call if the heater has no hot water and the light stays on well after shutdown.29

1 flash, about every 4 seconds The pilot is on and the main burner is idle. Safe to check yourself

Green light: 1 flash, about every 4 seconds.

Next step: No service is needed for this normal pattern.29

1 flash every second The main burner is heating the water. Safe to check yourself

Green light: 1 flash every second.

Next step: No service is needed for this normal pattern.29

2 flashes The pilot is supplying too little power for the main burner to start. Licensed technician only

Amber light: 2 flashes, then a 3-second pause.

Likely causes: A weak pilot flame; A loose connection to the pilot power cell (thermopile)

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29

4 flashes The heater shut down when the tank reached its high temperature limit. Licensed technician only

Red light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29

5 flashes The control detected a problem with its electronics, temperature sensor or gas valve. Licensed technician only

Red light: 5 flashes, then a 3-second pause.

Likely causes: A faulty temperature sensor or connection; A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29

6 flashes An add-on sensor detected water around the heater. Shut off safely and call a plumber

6 flashes, then a 3-second pause.

Only on ICON 2.0 models with the leak accessory and this code in their manual.

Likely cause: A leak leaving water around the heater

If you see steam or water spraying from the relief pipe, get outside and call 911 from outside. Stay back if water is near the heater’s wiring, plug or breaker panel. Look for water only from a dry spot after the cold water and every power or gas shutoff required by your heater’s manual are off. The front OFF button alone does not count. If you cannot shut it off safely, skip the check and call a licensed plumber.

Shutoff steps for each type of heater

Next step: Call a licensed plumber when this leak code appears, even if no water is visible.30

ICON Power Vent, Power Direct Vent or fan assist

Control low on the front with a separate on/off rocker above the temperature dial on the right and a green lamp near the upper-right corner.

Look for a powered blower at the top beside the vent and a power cord.31 Used on: ICON units in the PV, PDV and RG*F fan-assisted families covered by the quick guide. Also the RG2PDV and LG2PDV models in the PDV service manual.

No light The switch may be off or the gas control may have lost electrical power. Safe to check yourself

Likely causes: The heater switch is off; The power supply was interrupted

Safe to check:

  • If the area is dry and safe, look to see whether the breaker has tripped.

Next step: Call a licensed technician if you have no hot water and this pattern continues.32

Bright and dim The thermostat is asking for heat. Safe to check yourself

Green light: Alternating bright and dim.

Next step: No service is needed for this normal pattern.32

1 flash every second The control picked up a weak pilot signal on the last heating cycle. Licensed technician only

Green light: 1 flash every second.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

1 flash, about every 4 seconds The tank is up to temperature and the heater is waiting. Safe to check yourself

Green light: 1 flash, about every 4 seconds.

Next step: No service is needed for this normal pattern.32

2 flashes The air-pressure switch stayed closed when it should have opened. Licensed technician only

Green light: 2 flashes, then a 3-second pause.

Likely causes: A faulty pressure switch; A blocked or kinked air tube

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

3 flashes The air-pressure or blower temperature switch stayed open. Licensed technician only

Green light: 3 flashes, then a 3-second pause.

Likely causes: A vent blockage; A blower or switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

4 flashes The control shut down because the tank temperature was too high. Licensed technician only

Green light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

5 flashes The heater detected a pilot flame at the wrong time. Licensed technician only

Green light: 5 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

6 flashes, then 1 The pilot did not light. Licensed technician only

Green light: 6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33

6 flashes, then 2 The air-pressure or temperature switch opened while the burner was on. Licensed technician only

Green light: 6 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A vent blockage; A blower or switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33

6 flashes, then 3 The pilot went out during a heating cycle. Licensed technician only

Green light: 6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33

6 flashes, then 4 The control locked out after detecting a pilot flame at the wrong time. Licensed technician only

Green light: 6 flashes, then 4 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33

7 flashes Leave the area first The control flagged the flammable-vapor sensor input. On certain models the fault can be in the factory harness instead.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 7 flashes, then a 3-second pause.

Likely causes: Flammable vapors; A fault in the vapor-sensing circuit; An out-of-range sensor circuit on models using a factory resistor harness

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.33

8 flashes, then 1 Leave the area first The control detected an out-of-range reading at the flammable-vapor sensor input. Some models use a factory harness at this input.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 8 flashes, then 1 flash, then a 3-second pause.

Likely causes: A faulty vapor sensor; A possible short in the sensing circuit; An out-of-range sensor circuit on models using a factory resistor harness

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.33

8 flashes, then 2 The tank temperature sensor is giving a faulty reading. Licensed technician only

Green light: 8 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A damaged sensor or wire; A loose connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33

8 flashes, then 3 The gas valve detected an electronics fault. Licensed technician only

Green light: 8 flashes, then 3 flashes, then a 3-second pause.

Likely causes: Moisture or damage to the gas control; An internal control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33

8 flashes, then 4 The heater detected a gas valve fault. Licensed technician only

Green light: 8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A damaged or failing gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.33

Programmable Efficiency Defender

Look for a separate programmable box on the side of the tank and a corded blower on top.

The oblong low-front gas control has the separate ON/OFF rocker near its top center and a green lamp above the temperature dial on the right.34 Used on: PE4403S, PE440T, PE4503F and PE2XR504T variants listed in the PE supplement.

No light The switch may be off or the gas control may have lost electrical power. Safe to check yourself

Likely causes: The heater switch is off; The power supply was interrupted

Safe to check:

  • If the area is dry and safe, look to see whether the breaker has tripped.

Next step: Call a licensed technician if you have no hot water and this pattern continues.35

Bright and dim The thermostat is asking for heat. Safe to check yourself

Green light: Alternating bright and dim.

Next step: No service is needed for this normal pattern.35

1 flash every second The control picked up a weak pilot signal on the last heating cycle. Licensed technician only

Green light: 1 flash every second.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35

1 flash, about every 4 seconds The tank is up to temperature and the heater is waiting. Safe to check yourself

Green light: 1 flash, about every 4 seconds.

Next step: No service is needed for this normal pattern.35

2 flashes The control reported a fault with its safety relay. Licensed technician only

Green light: 2 flashes, then a 3-second pause.

Likely cause: A faulty relay

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35

3 flashes The control reported a fault with its safety relay. Licensed technician only

Green light: 3 flashes, then a 3-second pause.

Likely cause: A faulty relay

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35

4 flashes The control shut down because the tank temperature was too high. Licensed technician only

Green light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35

5 flashes The heater detected a pilot flame at the wrong time. Licensed technician only

Green light: 5 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35

6 flashes, then 1 The pilot did not light. Licensed technician only

Green light: 6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.35

6 flashes, then 2 The relay stopped working properly while the burner was on. Licensed technician only

Green light: 6 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A failing relay

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36

6 flashes, then 3 The pilot went out during a heating cycle. Licensed technician only

Green light: 6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36

6 flashes, then 4 The control locked out after detecting a pilot flame at the wrong time. Licensed technician only

Green light: 6 flashes, then 4 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36

7 flashes Leave the area first The heater flagged the flammable-vapor sensor or a thermal safety switch.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 7 flashes, then a 3-second pause.

Likely causes: Flammable vapors; Moisture or extreme temperature affecting the vapor sensor; An open thermal safety switch

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.36

8 flashes, then 1 Leave the area first The flammable-vapor sensor reading is outside its normal range.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 8 flashes, then 1 flash, then a 3-second pause.

Likely causes: A faulty vapor sensor; A possible short in the sensing circuit

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.36

8 flashes, then 3 The control flagged the tank temperature probe or the gas valve electronics. Licensed technician only

Green light: 8 flashes, then 3 flashes, then a 3-second pause.

Likely causes: A damaged or unplugged temperature probe; A failing gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36

8 flashes, then 4 The heater detected a gas valve fault. Licensed technician only

Green light: 8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A damaged or failing gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.36

RG Defender with powered vent damper

Control low on the tank with a separate power switch and temperature dial on the right.

The small status lamp is near the upper-right corner. Look for a motor box on the metal vent at the top and match the model on the rating plate. The vent flap cover distinguishes it from a blower housing when the valve faces look alike.37 Used on: RG1D and RG2D in the installation manual. Only look up a 6-2 pattern under the damper chart if the exact model documentation includes it.

No light The switch may be off or the gas control may have lost electrical power. Safe to check yourself

Likely causes: The heater switch is off; The power supply was interrupted

Safe to check:

  • If the area is dry and safe, look to see whether the breaker has tripped.

Next step: Call a licensed technician if you have no hot water and this pattern continues.38

Bright and dim The thermostat is asking for heat. Safe to check yourself

Alternating bright and dim.

Next step: No service is needed for this normal pattern.38

1 flash every second The control picked up a weak pilot signal on the last heating cycle. Licensed technician only

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38

1 flash, about every 4 seconds The tank is up to temperature and the heater is waiting. Safe to check yourself

Next step: No service is needed for this normal pattern.38

2 flashes The control detected a fault while checking the vent flap. Licensed technician only

2 flashes, then a 3-second pause.

Likely causes: A stuck vent flap; A vent blockage

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38

3 flashes The vent flap did not open all the way. Licensed technician only

3 flashes, then a 3-second pause.

Likely causes: A stuck vent flap; A vent blockage

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38

4 flashes The control shut down because the tank temperature was too high. Licensed technician only

4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38

5 flashes The heater detected a pilot flame at the wrong time. Licensed technician only

5 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38

6 flashes, then 1 The pilot did not light. Licensed technician only

6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.38

6 flashes, then 2 The vent flap moved away from fully open while the burner was on. Licensed technician only

6 flashes, then 2 flashes, then a 3-second pause.

Only if this pattern is listed for the exact model.

Likely causes: A vent blockage; A failing damper

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.39

6 flashes, then 3 The pilot went out during a heating cycle. Licensed technician only

6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40

6 flashes, then 4 The control locked out after detecting a pilot flame at the wrong time. Licensed technician only

6 flashes, then 4 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40

7 flashes Leave the area first The heater flagged the flammable-vapor sensor or a thermal safety switch.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

7 flashes, then a 3-second pause.

Likely causes: Flammable vapors; Moisture or extreme temperature affecting the vapor sensor; An open thermal safety switch

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.40

8 flashes, then 1 Leave the area first The flammable-vapor sensor reading is outside its normal range.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes, then 1 flash, then a 3-second pause.

Likely causes: A faulty vapor sensor; A possible short in the sensing circuit

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.40

8 flashes, then 2 The tank temperature sensor is giving a faulty reading. Licensed technician only

8 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A damaged sensor or wire; A loose connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40

8 flashes, then 3 The gas valve detected an electronics fault. Licensed technician only

8 flashes, then 3 flashes, then a 3-second pause.

Likely causes: Moisture or damage to the gas control; An internal control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40

8 flashes, then 4 The heater detected a gas valve fault. Licensed technician only

8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A damaged or failing gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.40

SIT electronic ICON

Light rectangular face with a round dial at upper left, a small status lens low below the printed instructions and a square igniter at lower right.

The face resembles electronic White-Rodgers. Confirm SIT in the exact heater manual.41 Used on: Standard Defender RG atmospheric models that list SIT as the fitted control in the July 2026 instructions.

No light The gas control has no power from the pilot. Safe to check yourself

Likely causes: The control is off; The pilot is out

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.42

Steady light The gas control is in shutdown after the knob was moved to OFF. Safe to check yourself

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call if the heater has no hot water and the light stays on well after shutdown.42

1 flash, about every 4 seconds The pilot is on and the main burner is idle. Safe to check yourself

Next step: No service is needed for this normal pattern.42

1 flash every second The main burner is heating the water. Safe to check yourself

Next step: No service is needed for this normal pattern.42

2 flashes The pilot is supplying too little power for the main burner to start. Licensed technician only

2 flashes, then a 3-second pause.

Likely causes: A weak pilot flame; A loose connection to the pilot power cell (thermopile)

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.42

4 flashes The heater shut down when the tank reached its high temperature limit. Licensed technician only

4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.42

5 flashes The control detected a problem with its electronics, temperature sensor or gas valve. Licensed technician only

5 flashes, then a 3-second pause.

Likely causes: A faulty temperature sensor or connection; A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.42

Earlier TTW, PDX or GXTW power vent

Low front gas control with a separate ON/OFF rocker and one status lamp.

Look for a powered blower and power cord. The face can resemble other powered ICON controls. Match a TTW, PDX or GXTW model to its manual.43 Used on: TTW, PDX and GXTW lines in the older quick guide. Use the exact TTW model manual for 8-2 or 8-3.

No light The switch may be off or the gas control may have lost electrical power. Safe to check yourself

Likely causes: The heater switch is off; The power supply was interrupted

Safe to check:

  • If the area is dry and safe, look to see whether the breaker has tripped.

Next step: Call a licensed technician if you have no hot water and this pattern continues.44

Bright and dim The thermostat is asking for heat. Safe to check yourself

Alternating bright and dim.

Next step: No service is needed for this normal pattern.44

1 flash every second The control picked up a weak pilot signal on the last heating cycle. Licensed technician only

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44

1 flash, about every 4 seconds The tank is up to temperature and the heater is waiting. Safe to check yourself

Next step: No service is needed for this normal pattern.44

2 flashes The air-pressure switch stayed closed when it should have opened. Licensed technician only

2 flashes, then a 3-second pause.

Likely causes: A faulty pressure switch; A blocked or kinked air tube

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44

3 flashes The air-pressure or blower temperature switch stayed open. Licensed technician only

3 flashes, then a 3-second pause.

Likely causes: A vent blockage; A blower or switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44

4 flashes The control shut down because the tank temperature was too high. Licensed technician only

4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44

5 flashes The heater detected a pilot flame at the wrong time. Licensed technician only

5 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.44

6 flashes, then 1 The pilot did not light. Licensed technician only

6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45

6 flashes, then 2 The air-pressure or temperature switch opened while the burner was on. Licensed technician only

6 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A vent blockage; A blower or switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45

6 flashes, then 3 The pilot went out during a heating cycle. Licensed technician only

6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45

6 flashes, then 4 The control locked out after detecting a pilot flame at the wrong time. Licensed technician only

6 flashes, then 4 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45

7 flashes Leave the area first The control flagged the flammable-vapor sensor input. On certain models the fault can be in the factory harness instead.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

7 flashes, then a 3-second pause.

Likely causes: Flammable vapors; A fault in the vapor-sensing circuit; An out-of-range factory resistor harness on certain TTW models

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.46

8 flashes, then 1 Leave the area first The control detected an out-of-range reading at the flammable-vapor sensor input. Some models use a factory harness at this input.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes, then 1 flash, then a 3-second pause.

Likely causes: A faulty vapor sensor; A possible short in the sensing circuit; An out-of-range factory resistor harness on certain TTW models

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.46

8 flashes, then 2 The tank temperature probe is damaged, disconnected or giving a faulty reading. Licensed technician only

Green light: 8 flashes, then 2 flashes, then a 3-second pause.

TTW models using the 238-46238A-00B service chart.

Likely cause: A damaged or loose temperature probe

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.47

8 flashes, then 3 The control flagged the tank temperature probe or the gas valve electronics. Licensed technician only

8 flashes, then 3 flashes, then a 3-second pause.

Check the exact manual. The TTW service manual limits 8-3 to electronics. The TTW/PDX/GXTW quick guide also lists the temperature probe.

Likely causes: A damaged or unplugged temperature probe; A failing gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.46

8 flashes, then 4 The heater detected a gas valve fault. Licensed technician only

8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A damaged or failing gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.45

Ultra Low NOx D Series with powered vent damper

Control low on the tank with a separate power switch and temperature dial on the right.

The small status lamp is near the upper-right corner. Look for a motor box on the metal vent at the top and match the model on the rating plate. Confirm the URG1D or URG2D model on the label.48 Used on: Natural-gas URG1D and URG2D Ultra Low NOx models in the service manual.

No light The switch may be off or the gas control may have lost electrical power. Safe to check yourself

Likely causes: The heater switch is off; The power supply was interrupted

Safe to check:

  • If the area is dry and safe, look to see whether the breaker has tripped.

Next step: Call a licensed technician if you have no hot water and this pattern continues.49

Bright and dim The thermostat is asking for heat. Safe to check yourself

Green light: Alternating bright and dim.

Next step: No service is needed for this normal pattern.49

1 flash every second The control picked up a weak pilot signal on the last heating cycle. Licensed technician only

Green light: 1 flash every second.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49

1 flash about every 2 seconds on the cited D Series chart The tank is up to temperature and the heater is waiting. Safe to check yourself

Green light: 1 flash about every 2 seconds on the cited D Series chart.

Next step: No service is needed for this normal pattern.50

2 flashes The control detected a fault while checking the vent flap. Licensed technician only

Green light: 2 flashes, then a 3-second pause.

Likely causes: A stuck vent flap; A vent blockage

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49

3 flashes The vent flap did not open all the way. Licensed technician only

Green light: 3 flashes, then a 3-second pause.

Likely causes: A stuck vent flap; A vent blockage

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49

4 flashes The control shut down because the tank temperature was too high. Licensed technician only

Green light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49

5 flashes The heater detected a pilot flame at the wrong time. Licensed technician only

Green light: 5 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.49

6 flashes, then 1 The pilot did not light. Licensed technician only

Green light: 6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51

6 flashes, then 2 The vent flap moved away from fully open while the burner was on. Licensed technician only

Green light: 6 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A faulty vent flap; A vent blockage

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51

6 flashes, then 3 The pilot went out during a heating cycle. Licensed technician only

Green light: 6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: An unstable pilot; A restricted pilot tube; A worn or dirty pilot electrode; Damaged pilot wiring

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51

6 flashes, then 4 The control locked out after detecting a pilot flame at the wrong time. Licensed technician only

Green light: 6 flashes, then 4 flashes, then a 3-second pause.

Likely causes: A pilot valve stuck open; A flame-sensor wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51

7 flashes Leave the area first The heater flagged the flammable-vapor sensor or a thermal safety switch.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 7 flashes, then a 3-second pause.

Likely causes: Flammable vapors; Moisture or extreme temperature affecting the vapor sensor; An open thermal safety switch

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.51

8 flashes, then 1 Leave the area first The flammable-vapor sensor reading is outside its normal range.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Green light: 8 flashes, then 1 flash, then a 3-second pause.

Likely causes: A faulty vapor sensor; A possible short in the sensing circuit

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.51

8 flashes, then 2 The tank temperature sensor is giving a faulty reading. Licensed technician only

Green light: 8 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A damaged sensor or wire; A loose connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51

8 flashes, then 3 The gas valve detected an electronics fault. Licensed technician only

Green light: 8 flashes, then 3 flashes, then a 3-second pause.

Likely causes: Moisture or damage to the gas control; An internal control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51

8 flashes, then 4 The heater detected a gas valve fault. Licensed technician only

Green light: 8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A damaged or failing gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.51

9 flashes, then 1 The burner is getting too little air. Licensed technician only

Green light: 9 flashes, then 1 flash, then a 3-second pause.

Likely cause: Restricted combustion air

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.52

9 flashes, then 2 The burner chamber temperature sensor is giving a reading outside its normal range. Licensed technician only

Green light: 9 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A faulty sensor; An electrical short

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.52

White-Rodgers electronic

Light gray face with a large black dial at upper left.

The green status lens is low near the middle, below the printed instructions. The separate dark igniter is at the lower right.53 Used on: Selected standard Defender RG and LG atmospheric models with the White-Rodgers electronic valve shown in the 2022 manual. Also DV Series with the matching valve.

No light The gas control has no power from the pilot. Safe to check yourself

Likely causes: The control is off; The pilot is out

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.54

Steady light The gas control is in shutdown after the knob was moved to OFF. Safe to check yourself

Green light: Steady light.

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call if the heater has no hot water and the light stays on well after shutdown.54

1 flash, about every 4 seconds The pilot is on and the main burner is idle. Safe to check yourself

Green light: 1 flash, about every 4 seconds.

Next step: No service is needed for this normal pattern.54

1 flash every second The main burner is heating the water. Safe to check yourself

Green light: 1 flash every second.

Next step: No service is needed for this normal pattern.54

2 flashes The pilot is supplying too little power for the main burner to start. Licensed technician only

Green light: 2 flashes, then a 3-second pause.

Likely causes: A weak pilot flame; A loose connection to the pilot power cell (thermopile)

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.54

4 flashes The heater shut down when the tank reached its high temperature limit. Licensed technician only

Green light: 4 flashes, then a 3-second pause.

Likely causes: A tank temperature sensor reading incorrectly; A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.54

5 flashes The control detected a problem with its electronics, temperature sensor or gas valve. Licensed technician only

Green light: 5 flashes, then a 3-second pause.

Likely causes: A faulty temperature sensor or connection; A gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.54

Not sure which control?

Look up a pattern on every control
No light Depends on the control

A dark lamp has different meanings on standing-pilot and plug-in or electric controls. Identify the heater before interpreting a dark lamp.

Steady light Depends on the control

Steady green means shutdown on some gas valves and normal standby on ICON E. Confirm gas versus electric.

Bright and dim The thermostat is asking for heat. Safe to check yourself
1 flash Depends on the control

A fast blink can mean normal heating on a standing-pilot valve or a weak pilot signal on powered models. Note how fast it blinks.

2 flashes Depends on the control

Two quick flashes can be normal on V1. The fault pattern can mean weak pilot power, an air-pressure switch, a damper fault or a relay fault.

The normal strobe uses two quick flashes close together. If you can’t tell it from the 2-flash pilot fault, check the manual for your exact heater or call a licensed technician.

3 flashes Depends on the control

Underheating on V1, a pressure or temperature switch on power vent, a damper on D Series, or a relay on the Programmable Efficiency model.

4 flashes Depends on the control

Four flashes can indicate a gas heater high-temperature cutoff, or an ICON E temperature sensor fault. Match the heater type and light color.

5 flashes Depends on the control

Tank sensor or control fault on standing-pilot units, or a pilot flame at the wrong time on powered units.

6 flashes Depends on the control

Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.

6 flashes, then 1 The pilot did not light. Licensed technician only

Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.

6 flashes, then 2 Depends on the control

Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.

6 flashes, then 3 The pilot went out during a heating cycle. Licensed technician only

Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.

6 flashes, then 4 The control locked out after detecting a pilot flame at the wrong time. Licensed technician only

Water at the leak sensor, a burner chamber sensor fault, or the first group of a two-part powered code. Record both groups.

7 flashes Could this be a flammable vapor warning? Leave now Depends on the control

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Standing-pilot V1 indicates gas-control electronics. Powered gas models point to the flammable-vapor sensing circuit or a thermal switch. Red seven on an ICON E electric tank indicates high temperature. Confirm the power source, vent hardware and model label first.

8 flashes Could this be a flammable vapor warning? Leave now The control detected a pilot flame when the knob was off. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.10

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.

8 flashes, then 1 Leave the area first Depends on the control

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.10

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.

8 flashes, then 2 Depends on the control

A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.

8 flashes, then 3 Depends on the control

A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.

8 flashes, then 4 The heater detected a gas valve fault. Licensed technician only

A plain group of eight on V1 is a pilot flame fault. On powered controls, the second group distinguishes a vapor-sensor fault from a temperature sensor or gas-valve fault.

9 flashes An add-on sensor detected water around the heater. Shut off safely and call a plumber

Nine red flashes on ECO V2 indicate water at the leak sensor. On the Ultra Low NOx D Series, nine is the first group of a two-part burner air or chamber sensor code.

9 flashes, then 1 The burner is getting too little air. Licensed technician only

Nine red flashes on ECO V2 indicate water at the leak sensor. On the Ultra Low NOx D Series, nine is the first group of a two-part burner air or chamber sensor code.

9 flashes, then 2 The burner chamber temperature sensor is giving a reading outside its normal range. Licensed technician only

Nine red flashes on ECO V2 indicate water at the leak sensor. On the Ultra Low NOx D Series, nine is the first group of a two-part burner air or chamber sensor code.

10 flashes Depends on the control

Check whether you have ECO Defender V1 or V2. On V1 this means too little air reaches the burner. On V2 it means an abnormal pattern of temperatures in the burner chamber.

Alternating amber and green The electric control has just powered on or is running its first-fill safety check. Safe to check yourself

No status light: Mechanical Robertshaw, Mechanical White-Rodgers. This mechanical valve has no status light. Use the model's printed guide for a pilot or heating problem.

How old is your heater?

Sources

60 numbered notes from 35 documents
  1. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveA. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765↑
  2. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
  3. U.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
  4. Technical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, pages 2, 7. 2018-02-07U.S. Fire Administration: Home Fire Escape Plans↑
  5. A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 25. 100307779 / 2000560245 Rev. BSupports the scald hazard. The manual also describes turning off the gas supply during a large discharge. This site says to keep clear and leave instead, because the valves are next to the scalding water.A. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveSupports hazard. Evacuation and 911 escalation follow the project safety tier.Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 42. U334-0773(00)↑
  6. A. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Supports hazard and ignition precautions. Evacuation follows the project safety tier.Pacific Gas and Electric Company: Gas Safety↑
  7. Bradford White Corporation: DV Series direct-vent gas water heaters service manual, pages 1, 6, 7. 238-51636-00D Rev 10/20↑
  8. Bradford White Corporation: DV Series direct-vent gas water heaters service manual, page 6. 238-51636-00D Rev 10/20↑
  9. Bradford White Corporation: DV Series direct-vent gas water heaters service manual, page 7. 238-51636-00D Rev 10/20↑
  10. A. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Seven flashes is the vapor sensor lockout; eight then one is a sensor fault. The two need the full pattern to tell apart.Rheem Manufacturing Company: Professional Classic Power Vent gas water heater use and care manual, page 37. AP22511 Rev 02Seven flashes and eight-then-one are both vapor sensor outcomes.Eight-then-one is the vapor sensor fault, seven flashes the vapor lockout.Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 5. TB 1621Separates a sensor circuit fault from vapor detection. Escalation for unresolved patterns follows docs/facts.md.Separates a sensor circuit fault from vapor detection. Evacuation for a sensor fault follows the project safety tier.Pacific Gas and Electric Company: Gas Safety↑
  11. Bradford White Corporation: Early ECO-DEFENDER gas water heaters service manual, pages 1, 5. 47132A↑
  12. Bradford White Corporation: Early ECO-DEFENDER gas water heaters service manual, page 5. 47132A↑
  13. Bradford White Corporation: Early ECO-DEFENDER gas water heaters service manual, page 6. 47132A↑
  14. Bradford White Corporation: ECO Defender Series service manual, pages 1, 6. 238-51546-00C Rev 11/20Bradford White Corporation: Ultra Low NOx atmospheric and direct vent ICON 1.0 service supplement, page 1. 238-55594-00A↑
  15. Bradford White Corporation: ECO Defender Series service manual, page 6. 238-51546-00C Rev 11/20↑
  16. Bradford White Corporation: ECO Defender Series service manual, page 7. 238-51546-00C Rev 11/20↑
  17. Bradford White Corporation: ECO Defender Series service manual, pages 1, 8, 9. 238-51546-00C Rev 11/20↑
  18. Bradford White Corporation: ECO Defender Series service manual, page 8. 238-51546-00C Rev 11/20↑
  19. Bradford White Corporation: ECO Defender Series service manual, page 9. 238-51546-00C Rev 11/20↑
  20. Bradford White Corporation: ICON E electric water heater installation and operation manual, pages 1, 15. 238-54223-00D Rev 12/24Bradford White Corporation: ICON E electronic control quick start and service guide, page 1. 238-54399-00B Rev 11/22↑
  21. Bradford White Corporation: ICON E electric water heater installation and operation manual, page 15. 238-54223-00D Rev 12/24↑
  22. Bradford White Corporation: ICON E electric water heater installation and operation manual, page 15. 238-54223-00D Rev 12/24Bradford White Corporation: ICON E electronic control quick start and service guide, page 1. 238-54399-00B Rev 11/22↑
  23. Bradford White Corporation: Defender residential atmospheric gas water heaters service manual, pages 1, 9. 238-51542-00E Rev 08/22Bradford White Corporation: ICON residential atmospheric and direct vent service supplement, page 2. 238-55592-00A (ICON 1.0, PDF p. 2)Bradford White Corporation: Gas-fired water heater installation and operation manual, including SIT, page 22. 238-51007-00R Rev 07/26Bradford White Corporation: Legacy Defender gas water heaters service manual, page 5. 238-44943-00D↑
  24. Bradford White Corporation: Defender residential atmospheric gas water heaters service manual, page 9. 238-51542-00E Rev 08/22Bradford White Corporation: Legacy Defender gas water heaters service manual, page 5. 238-44943-00D↑
  25. Bradford White Corporation: Gas-fired water heater installation and operation manual, including SIT, page 22. 238-51007-00R Rev 07/26↑
  26. Bradford White Corporation: Defender residential atmospheric gas water heaters service manual, page 10. 238-51542-00E Rev 08/22Bradford White Corporation: Legacy Defender gas water heaters service manual, page 5. 238-44943-00D↑
  27. Bradford White Corporation: Defender residential atmospheric gas water heaters service manual, page 10. 238-51542-00E Rev 08/22Bradford White Corporation: Legacy Defender gas water heaters service manual, page 6. 238-44943-00D↑
  28. Bradford White Corporation: Defender residential atmospheric gas water heaters service manual, pages 1, 11. 238-51542-00E Rev 08/22Bradford White Corporation: ICON residential atmospheric and direct vent service supplement, page 1. 238-55593-00A (ICON 2.0, PDF p. 1)Bradford White Corporation: DV Series direct-vent gas water heaters service manual, pages 1, 8. 238-51636-00D Rev 10/20↑
  29. Bradford White Corporation: Defender residential atmospheric gas water heaters service manual, page 11. 238-51542-00E Rev 08/22Bradford White Corporation: DV Series direct-vent gas water heaters service manual, page 8. 238-51636-00D Rev 10/20↑
  30. Bradford White Corporation: ICON residential atmospheric and direct vent service supplement, page 1. 238-55593-00A (ICON 2.0, PDF p. 1)↑
  31. Bradford White Corporation: ICON power vent, power direct vent and fan assist service supplement, page 1. 238-55968-00ABradford White Corporation: PDV Series power direct vent gas water heaters service manual, pages 1, 14. 238-51541-00C, 6/21Bradford White Corporation: PV Series power vent gas water heaters service manual, pages 1, 15. 238-51540-00E, 4/19↑
  32. Bradford White Corporation: ICON power vent, power direct vent and fan assist service supplement, page 1. 238-55968-00ABradford White Corporation: PDV Series power direct vent gas water heaters service manual, page 14. 238-51541-00C, 6/21Bradford White Corporation: PV Series power vent gas water heaters service manual, page 15. 238-51540-00E, 4/19↑
  33. Bradford White Corporation: ICON power vent, power direct vent and fan assist service supplement, page 1. 238-55968-00ABradford White Corporation: PDV Series power direct vent gas water heaters service manual, page 15. 238-51541-00C, 6/21Bradford White Corporation: PV Series power vent gas water heaters service manual, page 16. 238-51540-00E, 4/19↑
  34. Bradford White Corporation: Programmable Efficiency gas water heaters service supplement, pages 1, 13. 238-48494-00A↑
  35. Bradford White Corporation: Programmable Efficiency gas water heaters service supplement, page 13. 238-48494-00A↑
  36. Bradford White Corporation: Programmable Efficiency gas water heaters service supplement, page 14. 238-48494-00A↑
  37. Bradford White Corporation: Damper-equipped residential gas water heaters installation and operation manual, pages 1, 29. 238-51004-00B Rev 6/16Bradford White Corporation: ICON atmospheric damper service supplement, page 1. 238-55599-00A↑
  38. Bradford White Corporation: Damper-equipped residential gas water heaters installation and operation manual, page 29. 238-51004-00B Rev 6/16↑
  39. Bradford White Corporation: ICON atmospheric damper service supplement, page 1. 238-55599-00A↑
  40. Bradford White Corporation: Damper-equipped residential gas water heaters installation and operation manual, page 30. 238-51004-00B Rev 6/16↑
  41. Bradford White Corporation: Gas-fired water heater installation and operation manual, including SIT, pages 1, 15, 24. 238-51007-00R Rev 07/26↑
  42. Bradford White Corporation: Gas-fired water heater installation and operation manual, including SIT, page 24. 238-51007-00R Rev 07/26↑
  43. Bradford White Corporation: TTW, PDX and GXTW power vent service supplement, page 1. 238-56153-00ABradford White Corporation: PDV Series power direct vent gas water heaters service manual, page 14. 238-51541-00C, 6/21Bradford White Corporation: TTW through-the-wall gas water heaters service manual, pages 1, 13. 238-46238A-00B↑
  44. Bradford White Corporation: TTW, PDX and GXTW power vent service supplement, page 1. 238-56153-00ABradford White Corporation: TTW through-the-wall gas water heaters service manual, page 13. 238-46238A-00B↑
  45. Bradford White Corporation: TTW, PDX and GXTW power vent service supplement, page 1. 238-56153-00ABradford White Corporation: TTW through-the-wall gas water heaters service manual, page 14. 238-46238A-00B↑
  46. Bradford White Corporation: TTW, PDX and GXTW power vent service supplement, page 1. 238-56153-00ABradford White Corporation: TTW through-the-wall gas water heaters service manual, pages 14, 16. 238-46238A-00B↑
  47. Bradford White Corporation: TTW through-the-wall gas water heaters service manual, pages 14, 16. 238-46238A-00B↑
  48. Bradford White Corporation: Ultra Low NOx residential D Series gas water heaters service manual, pages 1, 11. 238-51673-00D, 6/21↑
  49. Bradford White Corporation: Ultra Low NOx residential D Series gas water heaters service manual, page 11. 238-51673-00D, 6/21↑
  50. Bradford White Corporation: Ultra Low NOx residential D Series gas water heaters service manual, page 11. 238-51673-00D, 6/21Bradford White Corporation: ICON atmospheric damper service supplement, page 1. 238-55599-00A↑
  51. Bradford White Corporation: Ultra Low NOx residential D Series gas water heaters service manual, page 12. 238-51673-00D, 6/21↑
  52. Bradford White Corporation: Ultra Low NOx residential D Series gas water heaters service manual, page 13. 238-51673-00D, 6/21↑
  53. Bradford White Corporation: Defender residential atmospheric gas water heaters service manual, pages 1, 8. 238-51542-00E Rev 08/22Bradford White Corporation: DV Series direct-vent gas water heaters service manual, pages 1, 11. 238-51636-00D Rev 10/20↑
  54. Bradford White Corporation: Defender residential atmospheric gas water heaters service manual, page 8. 238-51542-00E Rev 08/22Bradford White Corporation: DV Series direct-vent gas water heaters service manual, page 11. 238-51636-00D Rev 10/20↑
  55. A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 24. 100307779 / 2000560245 Rev. BA. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 14. 325321-000Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 53. U334-0773(00)Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape Plans
  56. A. O. Smith: Residential Electric Water Heaters, Models 6–120, page 12. 185762-002A. O. Smith: Is Your Hot Water Not Getting Hot? Common Causes & What To Do About ThemU.S. Fire Administration: Home Fire Escape Plans
  57. A. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveCenters for Disease Control and Prevention: Safety Guidelines: Reentering Your Flooded HomeA. O. Smith: Residential Electric Water Heaters, Models 6–120, page 19. 185762-002Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 65. U334-0773(00)
  58. Bradford White Corporation: Legacy Defender gas water heaters service manual, pages 1, 10, 11. 238-44943-00D
  59. Bradford White Corporation: Legacy Defender gas water heaters service manual, pages 1, 10. 238-44943-00DBradford White Corporation: Gas-fired water heater installation and operation manual, including SIT, page 14. 238-51007-00R Rev 07/26Bradford White Corporation: DV Series direct-vent gas water heaters service manual, page 9. 238-51636-00D Rev 10/20
  60. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveTechnical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, page 2. 2018-02-07Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 54. U334-0773(00)

Facts checked November 27, 2026, against documents retrieved November 27, 2026. Independent site, not affiliated with Bradford White. Your heater’s manual and label are the final word. In an emergency, get everyone outside first and call 911 from a safe spot outside. How we check facts