A. O. Smith water heater flashing codes

Covers A. O. Smith and State gas heaters.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2
Carbon monoxide alarm? Get outside

Get everyone to fresh air outside right away and call 911. Stay outside until emergency responders say it is safe to go back in.3

Flames coming out of the heater, smoke, or burn marks or melted parts that might be new? Get outside

If you see flames coming out of the heater, smoke, or signs it may still be burning, get everyone out and call 911 from outside. Leave the heater and switches alone. If you find unexplained burn marks or melted parts and can’t tell whether there’s an active fire, get outside and call 911. If you know the damage is old and there are no other emergency signs, keep the heater out of use and call a licensed technician.4

Water gushing or spraying from the safety valve’s pipe, or hot spray or steam near the heater? Leave now

The relief pipe is the pipe from the heater’s pressure safety valve. Keep clear of the heater, pipe and valves, even if you can’t tell where hot spray is coming from. Leave by a safe route and call 911 from outside. A slow drip without steam or other warning signs calls for safe shutoff and a plumber.5

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Every code, by control

Older Intelli-Vent with vapor sensing

Cream rectangular control with six little lights in a horizontal row.

The last three are marked A, B and C. The triangle is over the third light. There are blue COOLER and red HOTTER buttons below the row instead of a round dial. Look for VAC at the left end of the row. Match the model to the FVIR Intelli-Vent chart.7 Used on: Older A. O. Smith and State FVIR powered gas units equipped with the White-Rodgers Intelli-Vent covered by TB-A028-06.

Lights 1 and 3 on The air-pressure switch circuit stayed closed after the heating cycle began. Licensed technician only

Lights 1, 3 on, left to right.

Likely causes: A stuck pressure switch; A wiring problem

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

Lights 1 and 4 on The control cannot detect a proper electrical ground. Licensed technician only

Lights 1, 4 on, left to right.

Likely cause: A missing or loose ground connection

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

Lights 1 and 5 on The heater sensed a flame at the wrong time. Licensed technician only

Lights 1, 5 on, left to right.

Likely cause: A flame sensor or gas control fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

Lights 1 and 6 on Leave the area first The heater locked out after detecting flammable vapors.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Lights 1, 6 on, left to right.

Likely cause: Flammable vapors near the heater

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.10

Lights 1, 3 and 4 on The control thinks a temperature button is stuck. Licensed technician only

Lights 1, 3, 4 on, left to right.

Likely cause: A stuck button or control fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

Lights 1, 3 and 5 on The control detected reversed electrical supply wiring. Licensed technician only

Lights 1, 3, 5 on, left to right.

Likely causes: Reversed supply wires; A grounding fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

Lights 1, 3 and 6 on The air-pressure switch stayed open after the fan started. Licensed technician only

Lights 1, 3, 6 on, left to right.

Likely causes: A vent blockage; A blower, pressure switch or wiring problem

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

Lights 1, 4 and 5 on The burner failed to light or stay lit after several tries. Licensed technician only

Lights 1, 4, 5 on, left to right.

Likely causes: Poor gas supply; An igniter or flame sensor fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

Lights 1, 4 and 6 on Leave the area first The control detected a fault in the flammable-vapor sensor circuit.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.11

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Lights 1, 4, 6 on, left to right.

Likely causes: A damaged or disconnected vapor sensor; An electrical short

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.12

Lights 1, 5 and 6 on The control detected an internal electronics fault. Licensed technician only

Lights 1, 5, 6 on, left to right.

Likely cause: A failing valve drive or control circuit

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

Lights 1, 3, 4 and 5 on The control detected an internal electronics fault. Licensed technician only

Lights 1, 3, 4, 5 on, left to right.

Likely cause: A failing valve drive or control circuit

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

Lights 1, 3, 4 and 6 on The tank temperature sensor circuit has a fault. Licensed technician only

Lights 1, 3, 4, 6 on, left to right.

Likely cause: An open or shorted sensor circuit

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

Lights 1, 3, 5 and 6 on The controller detected a fault in the electric igniter circuit. Licensed technician only

Lights 1, 3, 5, 6 on, left to right.

Likely cause: A damaged igniter or wiring

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.8

Lights 1, 4, 5 and 6 on The tank reached the high temperature cutoff. Licensed technician only

Lights 1, 4, 5, 6 on, left to right.

Likely cause: Excessive tank temperature

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

Lights 1, 3, 4, 5 and 6 on The heater locked out after the air-pressure safety circuit opened repeatedly. Licensed technician only

Lights 1, 3, 4, 5, 6 on, left to right.

Likely causes: Restricted burner or vent airflow; A switch fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.13

Lights 1, 2, 3, 4, 5 and 6 on The control detected an internal electronics fault. Licensed technician only

Lights 1, 2, 3, 4, 5, 6 on, left to right.

Likely cause: A failing valve drive or control circuit

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.9

Honeywell Power Vent or Power Direct Vent, single light

Low rectangular control with one status lamp and a round temperature knob beside a separate ON/OFF switch.

Look for a powered blower and cord up at the vent. Use the model and its manual to distinguish it from a powered damper control.14 Used on: ProLine XE GPVL, GPVT and GPVX in the listed series and matching State GS6 power-vent families equipped with the single-LED gas control and a hot surface igniter.

Bright and dim The heater is calling for heat. Safe to check yourself

Alternating bright and dim.

Next step: No service is needed for this normal pattern.15

1 flash every 3 seconds The control picked up a weak flame signal. Licensed technician only

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

1 flash, about every 4 seconds The tank is up to temperature and waiting. Safe to check yourself

Next step: No service is needed for this normal pattern.15

2 flashes The air-pressure switch stayed closed when it should have opened. Licensed technician only

2 flashes, then a 3-second pause.

Likely cause: A stuck pressure switch or a wiring fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

3 flashes The air-pressure switch stayed open when it should have closed. Licensed technician only

3 flashes, then a 3-second pause.

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

4 flashes The tank reached the high temperature cutoff. Licensed technician only

4 flashes, then a 3-second pause.

Likely cause: Water above the tank temperature limit

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

5 flashes The control detected a flame at the wrong time. Licensed technician only

5 flashes, then a 3-second pause.

Likely cause: A flame-sensing or gas-control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

6 flashes, then 1 The heater paused after repeated failed attempts to light. Licensed technician only

6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

6 flashes, then 2 The heater paused after a pressure or temperature safety switch opened during operation. Licensed technician only

6 flashes, then 2 flashes, then a 3-second pause.

Likely causes: A blocked vent; A blower or pressure switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

6 flashes, then 3 The heater paused after losing its flame during operation. Licensed technician only

6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

6 flashes, then 4 The heater paused after sensing a flame at the wrong time. Licensed technician only

6 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A flame-sensing or gas-control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

7 flashes Leave the area first The flammable-vapor sensor put the heater in lockout.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

7 flashes, then a 3-second pause.

Likely cause: Flammable vapors near the heater

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.15

8 flashes, then 1 Leave the area first The heater detected a flammable-vapor sensor fault.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.11

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes, then 1 flash, then a 3-second pause.

Likely cause: A fault in the vapor sensor or its circuit

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.15

8 flashes, then 2 The heater detected a tank temperature sensor fault. Licensed technician only

8 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A faulty tank sensor or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

8 flashes, then 3 The gas control detected an electronics fault. Licensed technician only

8 flashes, then 3 flashes, then a 3-second pause.

Likely cause: A faulty gas control module

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

8 flashes, then 4 The heater detected a fault in the gas valve or its control. Licensed technician only

8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A faulty gas valve or control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.15

Single-light standing-pilot gas valve

Low on the front of the tank, with a rectangular light gray face.

The large dark dial at left has OFF and PILOT positions. A small STATUS light is to the right and a separate igniter button is below the dial. Some dials include VAC.16 Used on: A. O. Smith ProLine atmospheric and direct-vent standing-pilot models and State atmospheric models whose manual shows the same flash chart.

No light The pilot may be out, or it may be lit while the pilot power cell warms up or supplies too little power. Safe to check yourself

Likely causes: Pilot out; Pilot power cell warming up or producing too little power

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call a licensed technician if you have no hot water and this pattern continues.17

Steady light The pilot just went out and the pilot power cell is still cooling. Safe to check yourself

Red light: Steady light.

Likely cause: The pilot was recently turned off

Safe to check:

  • Read the knob position without moving it. Record it only if it’s safe to do so.

Next step: Call if the light stays on well after shutdown or the heater has no hot water.18

1 flash The heater is operating normally. Safe to check yourself

1 flash every 3 seconds.

Next step: No service is needed for this normal pattern.17

2 flashes The pilot supplies too little power for the gas control to work properly. Licensed technician only

Likely cause: A loose connection or a bad pilot power cell (thermopile)

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.17

4 flashes The control reported that the tank temperature reached its safety limit or that the limit circuit failed. Licensed technician only

Likely causes: High tank temperature; A gas control or temperature sensor fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.19

5 flashes The control detected a failed tank temperature sensor. Licensed technician only

Likely cause: A faulty temperature sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.20

7 flashes The gas valve or its control has failed. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.11

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Likely cause: A faulty gas control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.20

8 flashes The control kept getting power from the pilot after the knob was turned off. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.11

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Likely causes: A slow-cooling pilot power cell; A stuck pilot valve

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.20

Vertex GPHE-50 Intelli-Vent

Cream rectangular control with six little lights in a horizontal row.

The last three are marked A, B and C. The triangle marks the third light. There are blue COOLER and red HOTTER buttons below the row instead of a round dial. The left end is marked VAC on the valve. Confirm GPHE-50 on the tank model label.21 Used on: Vertex GPHE-50 using the user control shown in installation manual 100341945.

Lights 1 and 3 on The air-pressure switch circuit stayed closed after the heating cycle began. Licensed technician only

Lights 1, 3 on, left to right.

Likely causes: A stuck pressure switch; A wiring problem

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

Lights 1 and 5 on The heater sensed a flame at the wrong time. Licensed technician only

Lights 1, 5 on, left to right.

Likely cause: A flame sensor or gas control fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.23

Lights 1, 3 and 4 on The control thinks a temperature button is stuck. Licensed technician only

Lights 1, 3, 4 on, left to right.

Likely cause: A stuck button or control fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.23

Lights 1, 3 and 5 on The control detected a problem with its electrical supply wiring. Licensed technician only

Lights 1, 3, 5 on, left to right.

Likely causes: Reversed supply wires; A grounding fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

Lights 1, 3 and 6 on The air-pressure switch stayed open after the fan started. Licensed technician only

Lights 1, 3, 6 on, left to right.

Likely causes: A vent blockage; A blower, pressure switch or wiring problem

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

Lights 1, 4 and 5 on The burner failed to light or stay lit after several tries. Licensed technician only

Lights 1, 4, 5 on, left to right.

Likely causes: Poor gas supply; An igniter or flame sensor fault

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.23

Lights 1, 4 and 6 on The control cannot detect a proper electrical ground. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.11

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.11

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Lights 1, 4, 6 on, left to right.

Likely cause: A missing or loose ground connection

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

Lights 1, 3, 4 and 5 on The controller detected an internal electronics fault. Licensed technician only

Lights 1, 3, 4, 5 on, left to right.

Likely cause: A fault in the valve drive or another control circuit

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.23

Lights 1, 3, 5 and 6 on The controller detected a fault in the electric igniter circuit. Licensed technician only

Lights 1, 3, 5, 6 on, left to right.

Likely cause: A damaged igniter or wiring

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.22

Lights 1, 2, 3, 4, 5 and 6 on The controller detected an internal electronics fault. Licensed technician only

Lights 1, 2, 3, 4, 5, 6 on, left to right.

Likely cause: A fault in the valve drive or another control circuit

Safe to check:

  • Write down which lights are on, left to right. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.23

Lights 1, 5 and 6 onWe can’t confirm this code for your heater

We can’t confirm this code for your heater. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside now. Call 911 from a safe place outside. Leave the heater and switches alone. If you see steam near the heater or water gushing or spraying from the relief pipe, get outside and call 911 from outside. Do the same if you find unexplained burn marks or melted parts and can’t tell if there is an active fire. If there are no warning signs, contact the manufacturer or a licensed technician with your model number and the full code or flash pattern.24

Lights 1, 3, 4 and 6 onWe can’t confirm this code for your heater

We can’t confirm this code for your heater. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside now. Call 911 from a safe place outside. Leave the heater and switches alone. If you see steam near the heater or water gushing or spraying from the relief pipe, get outside and call 911 from outside. Do the same if you find unexplained burn marks or melted parts and can’t tell if there is an active fire. If there are no warning signs, contact the manufacturer or a licensed technician with your model number and the full code or flash pattern.24

ProLine XE powered flue damper

Low front gas valve with one status light, a round temperature dial and a separate power switch.

Look for a motorized flap (vent damper) at the top of the metal exhaust pipe.25 Used on: ProLine XE atmospheric gas tanks with automatic flue damper and chart 100400765. Match the model if the valve looks like another powered control.

Bright and dim The heater is calling for heat. Safe to check yourself

Alternating bright and dim.

Next step: No service is needed for this normal pattern.26

1 flash every 3 seconds The control picked up a weak flame signal. Licensed technician only

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.26

1 flash, about every 4 seconds The tank is up to temperature and waiting. Safe to check yourself

Next step: No service is needed for this normal pattern.26

2 flashes The vent damper's position switch stayed closed. Licensed technician only

2 flashes, then a 3-second pause.

Likely cause: A stuck damper or faulty position switch

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.26

3 flashes The vent damper's position switch stayed open or the burner door safety switch tripped. Licensed technician only

3 flashes, then a 3-second pause.

Likely causes: A stuck damper or faulty position switch; A tripped temperature cutoff

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.26

4 flashes The tank reached the high temperature cutoff. Licensed technician only

4 flashes, then a 3-second pause.

Likely cause: Water above the tank temperature limit

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.26

5 flashes The control detected a flame at the wrong time. Licensed technician only

5 flashes, then a 3-second pause.

Likely cause: A flame-sensing or gas-control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.26

6 flashes, then 1 The heater paused after repeated failed attempts to light. Licensed technician only

6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

6 flashes, then 2 The heater paused after losing its flame when the damper position switch failed. Licensed technician only

6 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A damper or its position switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

6 flashes, then 3 The heater paused after losing its flame during operation. Licensed technician only

6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

6 flashes, then 4 The heater paused after sensing a flame at the wrong time. Licensed technician only

6 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A flame-sensing or gas-control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

7 flashes Leave the area first The flammable-vapor sensor put the heater in lockout.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

7 flashes, then a 3-second pause.

Likely cause: Flammable vapors near the heater

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.27

8 flashes, then 1 Leave the area first The heater detected a flammable-vapor sensor fault.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.11

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes, then 1 flash, then a 3-second pause.

Likely cause: A fault in the vapor sensor or its circuit

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.27

8 flashes, then 2 The heater detected a tank temperature sensor fault. Licensed technician only

8 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A faulty tank sensor or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

8 flashes, then 3 The gas control detected an electronics fault. Licensed technician only

8 flashes, then 3 flashes, then a 3-second pause.

Likely cause: A faulty gas control module

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

8 flashes, then 4 The heater detected a fault in the gas valve or its control. Licensed technician only

8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A faulty gas valve or control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.27

ProLine XE Ultra Low NOx flue damper, gas valve

Low front gas valve with one status light, a round temperature dial and a power switch.

Look for a motorized vent flap at the top and a separate LDO status box above the gas valve. This chart is for the light on the valve itself.28 Used on: Ultra Low NOx powered flue damper models with 100366638 Rev A chart, including compatible GUF series units.

No light The gas control is locked out. Its separate LDO module may show the reason. Licensed technician only

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29

Bright and dim The heater is calling for heat. Safe to check yourself

Alternating bright and dim.

Next step: No service is needed for this normal pattern.29

1 flash The control picked up a weak flame signal. Licensed technician only

1 flash every 3 seconds.

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29

2 flashes The vent damper's position switch stayed closed. Licensed technician only

2 flashes, then a 3-second pause.

Likely cause: A stuck damper or faulty position switch

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29

3 flashes The vent damper's position switch stayed open. Licensed technician only

3 flashes, then a 3-second pause.

Likely cause: A stuck damper or faulty position switch

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29

4 flashes The tank reached the high temperature cutoff. Licensed technician only

4 flashes, then a 3-second pause.

Likely cause: Water above the tank temperature limit

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29

5 flashes The control detected a flame at the wrong time. Licensed technician only

5 flashes, then a 3-second pause.

Likely cause: A flame-sensing or gas-control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.29

6 flashes, then 1 The heater paused after repeated failed attempts to light. Licensed technician only

6 flashes, then 1 flash, then a 3-second pause.

Likely causes: An interrupted gas supply; An igniter or gas control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

6 flashes, then 2 The heater paused after losing its flame when the damper position switch failed. Licensed technician only

6 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A damper or its position switch fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

6 flashes, then 3 The heater paused after losing its flame during operation. Licensed technician only

6 flashes, then 3 flashes, then a 3-second pause.

Likely causes: Low gas supply pressure; A weak or faulty flame sensor

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

6 flashes, then 4 The heater paused after sensing a flame at the wrong time. Licensed technician only

6 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A flame-sensing or gas-control fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.30

7 flashes Leave the area first The flammable-vapor sensor put the heater in lockout.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

7 flashes, then a 3-second pause.

Likely cause: Flammable vapors near the heater

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.31

8 flashes, then 1 Leave the area first The heater detected a flammable-vapor sensor fault.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.11

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

8 flashes, then 1 flash, then a 3-second pause.

Likely cause: A fault in the vapor sensor or its circuit

Next step: Arrange licensed service after emergency responders or the gas utility say the area is safe.31

8 flashes, then 2 The heater detected a tank temperature sensor fault. Licensed technician only

8 flashes, then 2 flashes, then a 3-second pause.

Likely cause: A faulty tank sensor or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.32

8 flashes, then 3 The gas control detected an electronics fault. Licensed technician only

8 flashes, then 3 flashes, then a 3-second pause.

Likely cause: A faulty gas control module

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.31

8 flashes, then 4 The heater detected a fault in the gas valve or its control. Licensed technician only

8 flashes, then 4 flashes, then a 3-second pause.

Likely cause: A faulty gas valve or control

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.31

ProLine XE Ultra Low NOx, separate LDO light

Small separate LDO status box mounted above the low front gas valve.

Use the indicator on that box and note whether the separate light on the gas valve is dark or alternating bright and dim.33 Used on: The LDO module in ProLine XE Ultra Low NOx flue damper models identified by 100366638 Rev A.

1 flash, about every 4 seconds The module reports a burner failure when the gas valve light is dark. Licensed technician only

Only when the gas valve light is dark.

Likely cause: A burner fault

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.31

1 flash every second The heater is working normally when the gas-valve light pulses bright and dim. Safe to check yourself

Only when the gas valve light is alternating bright and dim.

Next step: No service is needed for this normal pattern.31

2 flashes The module reports a chamber sensor failure while the gas valve light is dark. Licensed technician only

Two pulses, a four-second gap, then two pulses.

Only when the gas valve light is dark.

Likely cause: A faulty chamber temperature sensor or connection

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.31

Grouped pulses with a 1-second gap and gas valve light off The module detected a buildup of lint or dust while the gas valve light is dark. Licensed technician only

Only when the gas valve light is dark.

Likely cause: Lint and dust buildup

Safe to check:

  • Write down the full pattern and the model number. Record it only if it’s safe to do so.

Next step: Stop using the heater and call a licensed gas technician. Leave the covers in place and leave any restart or reset to the technician. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside and call 911 from outside. Leave the heater and switches alone.31

Not sure which control?

Look up a pattern on every control
No light Depends on the control

A dark standing-pilot light can mean no pilot power. A dark Ultra Low NOx valve light can mean lockout. Check which controller and light are present.

Steady light The pilot just went out and the pilot power cell is still cooling. Safe to check yourself
Bright and dim The heater is calling for heat. Safe to check yourself
1 flash Depends on the control

One blink about every three seconds is normal for the standing-pilot valve but can be a weak flame signal on powered valves. The separate LDO light has its own timings.

2 flashes Depends on the control

A weak pilot power supply, a pressure switch issue, a damper switch issue or the separate LDO chamber sensor pattern.

3 flashes Depends on the control

Confirm the light and vent type to distinguish a power-vent pressure switch, a damper switch and the LDO lint alert.

4 flashes Depends on the control
5 flashes Depends on the control

A tank temperature sensor fault on a standing-pilot valve and a flame at the wrong time on powered valves.

6 flashes, then 1 The heater paused after repeated failed attempts to light. Licensed technician only

Record both flash groups. Six followed by two can indicate a pressure or temperature switch on power-vent models or a damper position switch on damper models.

6 flashes, then 2 Depends on the control

Record both flash groups. Six followed by two can indicate a pressure or temperature switch on power-vent models or a damper position switch on damper models.

6 flashes, then 3 The heater paused after losing its flame during operation. Licensed technician only

Record both flash groups. Six followed by two can indicate a pressure or temperature switch on power-vent models or a damper position switch on damper models.

6 flashes, then 4 The heater paused after sensing a flame at the wrong time. Licensed technician only

Record both flash groups. Six followed by two can indicate a pressure or temperature switch on power-vent models or a damper position switch on damper models.

7 flashes Could this be a flammable vapor warning? Leave now Depends on the control

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.11

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

A gas valve fault on standing-pilot models. A flammable-vapor sensor lockout on power vent and powered damper models.

8 flashes Could this be a flammable vapor warning? Leave now The control kept getting power from the pilot after the knob was turned off. Licensed technician only

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.11

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Eight by itself is continued pilot power after shutdown on standing-pilot models. A second group changes the diagnosis on powered models.

8 flashes, then 1 Leave the area first The heater detected a flammable-vapor sensor fault.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.11

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

Eight by itself is continued pilot power after shutdown on standing-pilot models. A second group changes the diagnosis on powered models.

8 flashes, then 2 The heater detected a tank temperature sensor fault. Licensed technician only

Eight by itself is continued pilot power after shutdown on standing-pilot models. A second group changes the diagnosis on powered models.

8 flashes, then 3 The gas control detected an electronics fault. Licensed technician only

Eight by itself is continued pilot power after shutdown on standing-pilot models. A second group changes the diagnosis on powered models.

8 flashes, then 4 The heater detected a fault in the gas valve or its control. Licensed technician only

Eight by itself is continued pilot power after shutdown on standing-pilot models. A second group changes the diagnosis on powered models.

Lights 1 and 3 on The air-pressure switch circuit stayed closed after the heating cycle began. Licensed technician only
Lights 1 and 4 on The control cannot detect a proper electrical ground. Licensed technician only
Lights 1 and 5 on The heater sensed a flame at the wrong time. Licensed technician only
Lights 1 and 6 on Leave the area first The heater locked out after detecting flammable vapors.

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Heater shows a flammable vapor warning or lockout? Leave now, even if you smell nothing

A warning that the heater detected flammable vapors is enough to leave, even if you see no smoke and smell nothing. Leave switches, flames and heater controls alone. Call 911 from a safe place outside and describe the exact warning. Have a licensed gas technician check the heater before it is used again.6

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2
Lights 1, 3 and 4 on The control thinks a temperature button is stuck. Licensed technician only
Lights 1, 3 and 5 on Depends on the control
Lights 1, 3 and 6 on The air-pressure switch stayed open after the fan started. Licensed technician only
Lights 1, 4 and 5 on The burner failed to light or stay lit after several tries. Licensed technician only
Lights 1, 4 and 6 on Could this be a flammable vapor warning? Leave now Depends on the control

Before you continue

If any of these is happening, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.1

Could this be a flammable vapor warning? Leave now

This may be a flammable vapor warning. If the model and exact pattern you already know don’t rule it out, get everyone outside now and call 911 from a safe place outside. Leave the heater and switches alone.11

Flammable vapor sensor fault? Leave now

The heater reports a fault in its flammable-vapor sensor circuit. Get everyone outside now. Leave switches and heater controls alone. Call 911 from outside and report the sensor fault and exact code. Have a licensed gas technician check the heater before it is used again.11

Smell gas or rotten eggs in the room, hear gas escaping (often a hiss), or unsure where a rotten-egg smell comes from? Leave now
  1. 1. Get everyone outside and well away from the building now.
  2. 2. On the way out, leave switches and appliance controls alone. Wait until you are safely outside to use your phone, and do not light a match or use any flame.
  3. 3. From a safe spot outside, call 911 and then your gas utility or propane supplier.2

This same six-light pattern can mean a fault in the flammable-vapor sensor circuit or a grounding fault. Confirm whether your heater uses the Vertex GPHE control or the older FVIR Intelli-Vent. If you’re unsure, follow the emergency steps.

Lights 1, 5 and 6 on Depends on the control

Vertex prints this pattern for both a control electronics fault and tank overheat. Match the exact Intelli-Vent chart.

This manual lists these same lights for two different faults. Have a licensed technician check which one applies.

On Vertex GPHE-50 Intelli-Vent:

We can’t confirm this code for your heater. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside now. Call 911 from a safe place outside. Leave the heater and switches alone. If you see steam near the heater or water gushing or spraying from the relief pipe, get outside and call 911 from outside. Do the same if you find unexplained burn marks or melted parts and can’t tell if there is an active fire. If there are no warning signs, contact the manufacturer or a licensed technician with your model number and the full code or flash pattern.24

Lights 1, 3, 4 and 5 on Depends on the control
Lights 1, 3, 4 and 6 on Depends on the control

Vertex groups a weak flame signal and a sensor fault under this same pattern. The older FVIR chart uses it for the temperature sensor.

This manual lists these same lights for both a water-sensor fault and a weak flame signal. Have a licensed technician check which one applies.

On Vertex GPHE-50 Intelli-Vent:

We can’t confirm this code for your heater. If you smell gas, hear gas escaping, hear a carbon monoxide alarm, or see smoke or flames, get outside now. Call 911 from a safe place outside. Leave the heater and switches alone. If you see steam near the heater or water gushing or spraying from the relief pipe, get outside and call 911 from outside. Do the same if you find unexplained burn marks or melted parts and can’t tell if there is an active fire. If there are no warning signs, contact the manufacturer or a licensed technician with your model number and the full code or flash pattern.24

Lights 1, 3, 5 and 6 on The controller detected a fault in the electric igniter circuit. Licensed technician only
Lights 1, 4, 5 and 6 on The tank reached the high temperature cutoff. Licensed technician only
Lights 1, 3, 4, 5 and 6 on The heater locked out after the air-pressure safety circuit opened repeatedly. Licensed technician only
Lights 1, 2, 3, 4, 5 and 6 on Depends on the control
ldo-lint The module detected a buildup of lint or dust while the gas valve light is dark. Licensed technician only

No status light: State mechanical Robertshaw, State mechanical White-Rodgers. This mechanical valve has no status light. Use the model's printed guide for a pilot or heating problem.

How old is your heater?

Sources

35 numbered notes from 23 documents
  1. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveA. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765↑
  2. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
  3. U.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Consumer Product Safety Commission: CPSC Urges Flood Victims to Take Steps to Prevent CO Poisoning, Electrocution, Explosion and Fires↑
  4. Technical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, pages 2, 7. 2018-02-07U.S. Fire Administration: Home Fire Escape Plans↑
  5. A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 25. 100307779 / 2000560245 Rev. BSupports the scald hazard. The manual also describes turning off the gas supply during a large discharge. This site says to keep clear and leave instead, because the valves are next to the scalding water.A. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveSupports hazard. Evacuation and 911 escalation follow the project safety tier.Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 42. U334-0773(00)↑
  6. A. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Supports hazard and ignition precautions. Evacuation follows the project safety tier.Pacific Gas and Electric Company: Gas Safety↑
  7. A. O. Smith Water Products Company: Residential Intelli-Vent troubleshooting guide, including FVIR bulletin, pages 7, 31. 320988-000, TB-A028-06 (2006)Bulletin page 1 of 5.↑
  8. A. O. Smith Water Products Company: Residential Intelli-Vent troubleshooting guide, including FVIR bulletin, page 31. 320988-000, TB-A028-06 (2006)Bulletin page 1 of 5.↑
  9. A. O. Smith Water Products Company: Residential Intelli-Vent troubleshooting guide, including FVIR bulletin, page 32. 320988-000, TB-A028-06 (2006)Bulletin page 2 of 5.↑
  10. A. O. Smith Water Products Company: Residential Intelli-Vent troubleshooting guide, including FVIR bulletin, page 34. 320988-000, TB-A028-06 (2006)Bulletin page 4 of 5.↑
  11. Rheem Manufacturing Company: Professional Classic Power Vent gas water heater use and care manual, page 37. AP22511 Rev 02Eight-then-one is the vapor sensor fault, seven flashes the vapor lockout.Seven flashes and eight-then-one are both vapor sensor outcomes.Rheem Manufacturing Company: Technical Service Bulletin 1621, White-Rodgers Intelli-Vent Guardian PowerVent, page 5. TB 1621Separates a sensor circuit fault from vapor detection. Evacuation for a sensor fault follows the project safety tier.Separates a sensor circuit fault from vapor detection. Escalation for unresolved patterns follows docs/facts.md.A. O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide, page 28. 100400765Seven flashes is the vapor sensor lockout; eight then one is a sensor fault. The two need the full pattern to tell apart.Pacific Gas and Electric Company: Gas Safety↑
  12. A. O. Smith Water Products Company: Residential Intelli-Vent troubleshooting guide, including FVIR bulletin, page 33. 320988-000, TB-A028-06 (2006)Bulletin page 3 of 5.↑
  13. A. O. Smith Water Products Company: Residential Intelli-Vent troubleshooting guide, including FVIR bulletin, page 35. 320988-000, TB-A028-06 (2006)Bulletin page 5 of 5.↑
  14. A. O. Smith Water Products Company: ProLine XE power-vented gas water heaters with hot surface ignition, pages 1, 14, 40, 41. 100366731 / 2000622624 Rev A, February 2023State Industries, Inc.: State residential gas power-vent heater with hot surface ignition, page 1. 100293470 / 2000545223 Rev A, 1708State Industries, Inc.: State residential gas power-vent heater with hot surface ignition, later models, page 1. 100309033 / 2000560886 Rev A, 1808↑
  15. A. O. Smith Water Products Company: ProLine XE power-vented gas water heaters with hot surface ignition, page 55. 100366731 / 2000622624 Rev A, February 2023State Industries, Inc.: State residential gas power-vent heater with hot surface ignition, page 56. 100293470 / 2000545223 Rev A, 1708State Industries, Inc.: State residential gas power-vent heater with hot surface ignition, later models, page 53. 100309033 / 2000560886 Rev A, 1808↑
  16. A. O. Smith Water Products Company: Residential atmospheric gas water heater use and care guide, pages 1, 23. 100263112, January 2015A. O. Smith Water Products Company: ProLine residential direct-vent gas water heaters installation and operating manual, page 42. 328740-000, 1404State Industries, Inc.: State residential atmospheric gas water heater use and care guide, page 34. 100276479 / 2000538798↑
  17. A. O. Smith Water Products Company: Residential atmospheric gas water heater use and care guide, page 27. 100263112, January 2015A. O. Smith Water Products Company: ProLine residential direct-vent gas water heaters installation and operating manual, page 42. 328740-000, 1404State Industries, Inc.: State residential atmospheric gas water heater use and care guide, page 34. 100276479 / 2000538798↑
  18. A. O. Smith Water Products Company: ProLine residential direct-vent gas water heaters installation and operating manual, page 42. 328740-000, 1404State Industries, Inc.: State residential atmospheric gas water heater use and care guide, page 34. 100276479 / 2000538798A. O. Smith Water Products Company: Residential atmospheric gas water heater use and care guide, page 23. 100263112, January 2015↑
  19. A. O. Smith Water Products Company: Residential atmospheric gas water heater use and care guide, page 27. 100263112, January 2015A. O. Smith Water Products Company: ProLine residential direct-vent gas water heaters installation and operating manual, page 43. 328740-000, 1404State Industries, Inc.: State residential atmospheric gas water heater use and care guide, page 34. 100276479 / 2000538798↑
  20. A. O. Smith Water Products Company: Residential atmospheric gas water heater use and care guide, page 27. 100263112, January 2015A. O. Smith Water Products Company: ProLine residential direct-vent gas water heaters installation and operating manual, page 43. 328740-000, 1404State Industries, Inc.: State residential atmospheric gas water heater use and care guide, page 35. 100276479 / 2000538798↑
  21. A. O. Smith Water Products Company: Vertex GPHE residential power-vent water heater installation manual, pages 1, 35, 43. 100341945 / 2000542152E, 0321↑
  22. A. O. Smith Water Products Company: Vertex GPHE residential power-vent water heater installation manual, page 35. 100341945 / 2000542152E, 0321↑
  23. A. O. Smith Water Products Company: Vertex GPHE residential power-vent water heater installation manual, page 36. 100341945 / 2000542152E, 0321↑
  24. Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape PlansA. O. Smith: Bulletin 52: Leaking Temperature and Pressure Relief ValveTechnical Safety BC: Incident Summary II-648560-2018: Natural gas water heater flame rollout, page 2. 2018-02-07Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 54. U334-0773(00)↑
  25. A. O. Smith Water Products Company: ProLine XE residential gas water heater with powered flue damper, pages 1, 2, 19, 36. 100400765 / 2000621411, November 2025↑
  26. A. O. Smith Water Products Company: ProLine XE residential gas water heater with powered flue damper, page 27. 100400765 / 2000621411, November 2025↑
  27. A. O. Smith Water Products Company: ProLine XE residential gas water heater with powered flue damper, page 28. 100400765 / 2000621411, November 2025↑
  28. A. O. Smith Water Products Company: Ultra Low NOx residential gas flue damper use and care guide, pages 1, 2, 25, 27. 100366638 / 2000622614 Rev A↑
  29. A. O. Smith Water Products Company: Ultra Low NOx residential gas flue damper use and care guide, page 28. 100366638 / 2000622614 Rev A↑
  30. A. O. Smith Water Products Company: Ultra Low NOx residential gas flue damper use and care guide, page 29. 100366638 / 2000622614 Rev A↑
  31. A. O. Smith Water Products Company: Ultra Low NOx residential gas flue damper use and care guide, page 30. 100366638 / 2000622614 Rev A↑
  32. A. O. Smith Water Products Company: Ultra Low NOx residential gas flue damper use and care guide, pages 27, 30. 100366638 / 2000622614 Rev A↑
  33. A. O. Smith Water Products Company: Ultra Low NOx residential gas flue damper use and care guide, pages 2, 30. 100366638 / 2000622614 Rev A↑
  34. A. O. Smith: Residential Atmospheric Gas Water Heater Use and Care Guide for Manufactured Homes, page 24. 100307779 / 2000560245 Rev. BA. O. Smith: Residential Ultra Low NOx Gas Water Heater, page 14. 325321-000Rinnai: Tankless Water Heater Installation and Operation Manual, RUR199i/e and RUR160i/e, page 53. U334-0773(00)Pacific Gas and Electric Company: Gas SafetyU.S. Consumer Product Safety Commission: Carbon Monoxide Fact SheetU.S. Fire Administration: Home Fire Escape Plans
  35. State Industries, Inc.: State FVIR gas water heater instruction manual, mechanical valves, page 5. 186489-002

Facts checked November 27, 2026, against documents retrieved November 27, 2026. Independent site, not affiliated with A. O. Smith or State. Your heater’s manual and label are the final word. In an emergency, get everyone outside first and call 911 from a safe spot outside. How we check facts